=== In Trending === | === In Trending === | ||
− | ==== ( | + | ==== (H) 3n spr: Unusable performance of ipsec tests with SHA_256_128 ==== |
− | * last update: | + | * last update: 2024-08-14 |
− | * work-to-fix: | + | * work-to-fix: low (if you are Damjan) |
− | * rca: | + | * rca: It seems compiler emits wrong instructions, VPP build system needs to be fixed. |
− | * test: | + | * test: Three new ipsec tests that use SHA_256_128 as integrity algorithm. |
− | * frequency: | + | * frequency: 50% |
− | * testbed: | + | * testbed: 3na-spr, 3nb-spr |
− | * example: [https://s3-logs.fd.io/vex-yul-rot-jenkins-1/csit-vpp-perf- | + | * example: [https://s3-logs.fd.io/vex-yul-rot-jenkins-1/csit-vpp-perf-report-iterative-2406-3na-spr/57/log.html.gz#s1-s1-s1-s1-s3-t1-k3-k7-k1-k1-k1-k8-k10-k1-k1-k1-k12] |
− | * ticket: [https://jira.fd.io/browse/ | + | * ticket: [https://jira.fd.io/browse/VPP-2118 VPP-2118] |
+ | * note: Other Xeon testbeds are also affected, but performance is not as bad to fail NDR. ARM is not affected at all. | ||
− | ==== ( | + | ==== (H) 3nb-spr hoststack: interface not up after first test ==== |
− | * last update: | + | * last update: 2024-02-07 |
* work-to-fix: medium | * work-to-fix: medium | ||
− | * rca: | + | * rca: After first test, HundredGigabitEthernetab/0/0 never goes up within the run. Not sure which part f test setup is missing, the tests do work correctly on other testbeds. |
− | * test: | + | * test: All subsequent tests. |
− | * frequency: | + | * frequency: 100% |
− | * testbed: | + | * testbed: 3nb-apr |
− | * example: [https://s3-logs.fd.io/vex-yul-rot-jenkins-1/csit- | + | * example: [https://s3-logs.fd.io/vex-yul-rot-jenkins-1/csit-vpp-perf-hoststack-daily-master-3nb-spr/87/log.html.gz#s1-s1-s1-s1-s1-t1-k2-k3-k7-k7] |
− | * ticket: [https://jira.fd.io/browse/CSIT- | + | * ticket: [https://jira.fd.io/browse/CSIT-1942 CSIT-1942] |
+ | |||
+ | ==== (H) Zero traffic reported in udpquic tests ==== | ||
+ | |||
+ | * last update: 2024-02-07 | ||
+ | * work-to-fix: medium | ||
+ | * rca: There are errors when closing sessions. The current CSIT logic happens to report this as a passing test with zero traffic, which is wrong. | ||
+ | * test: All tests udpquic tests | ||
+ | * frequency: 100% | ||
+ | * testbed: all running the tests | ||
+ | * example: [https://s3-logs.fd.io/vex-yul-rot-jenkins-1/csit-vpp-perf-hoststack-daily-master-3n-icx/217/log.html.gz#s1-s1-s1-s1-s4-t1-k2-k4-k17] | ||
+ | * ticket: [https://jira.fd.io/browse/CSIT-1935 CSIT-1935] | ||
+ | |||
+ | ==== (M) DPDK 23.03 testpmd startup fails on some testbeds ==== | ||
+ | |||
+ | * last update: 2023-11-06 | ||
+ | * work-to-fix: medium | ||
+ | * rca: The DUT-DUT link sometimes does not go up. The same consequences as CSIT-1848 but affects more testbed+NIC combinations. Can be fixed by a different startup procedure (better detection before for restart). | ||
+ | * test: Testpmd (no vpp). Around half of tested+NIC combinations are affected. | ||
+ | * frequency: Low, ~1%, as in most testbeds the link does go up. | ||
+ | * testbed: multiple | ||
+ | * example: [https://s3-logs.fd.io/vex-yul-rot-jenkins-1/csit-dpdk-perf-report-iterative-2310-2n-zn2/8/log.html.gz#s1-s1-s1-s1-t6-k2-k4] | ||
+ | * ticket: [https://jira.fd.io/browse/CSIT-1904 CSIT-1904] | ||
==== (M) 2n-spr: zero traffic on cx7 rdma ==== | ==== (M) 2n-spr: zero traffic on cx7 rdma ==== | ||
Line 55: | Line 78: | ||
* frequency: always (since 2n-spr was set up) | * frequency: always (since 2n-spr was set up) | ||
* testbed: 2n-spr | * testbed: 2n-spr | ||
− | * example: https://s3-logs.fd.io/vex-yul-rot-jenkins-1/csit-vpp-perf-mrr-daily-master-2n-spr/58/log.html.gz#s1-s1-s1-s5-s19-t1-k3-k7-k1-k1-k1-k8-k14-k1-k1-k1-k1 | + | * example: [https://s3-logs.fd.io/vex-yul-rot-jenkins-1/csit-vpp-perf-mrr-daily-master-2n-spr/58/log.html.gz#s1-s1-s1-s5-s19-t1-k3-k7-k1-k1-k1-k8-k14-k1-k1-k1-k1] |
* ticket: [https://jira.fd.io/browse/CSIT-1906 CSIT-1906] | * ticket: [https://jira.fd.io/browse/CSIT-1906 CSIT-1906] | ||
* note: Also would affect 3n-alt with mlxc6 and rdma. Will probably be made invisible by removing rdma (except mlxc5) from jobspecs. | * note: Also would affect 3n-alt with mlxc6 and rdma. Will probably be made invisible by removing rdma (except mlxc5) from jobspecs. | ||
− | ==== (M) | + | ==== (M) 3n-icx 3nb-spr: Failed to enable GTPU offload RX ==== |
− | * last update: | + | * last update: 2024-08-14 |
− | * work-to-fix: | + | * work-to-fix: low |
− | * rca: | + | * rca: Retval is -1. More examination is needed to understand why. |
− | * test: | + | * test: any gtpuhw |
− | * frequency: | + | * frequency: 100% |
− | * testbed: | + | * testbed: all |
− | * example: https://s3-logs.fd.io/vex-yul-rot-jenkins-1/csit- | + | * example: [https://s3-logs.fd.io/vex-yul-rot-jenkins-1/csit-vpp-perf-report-iterative-2406-3nb-spr/63/log.html.gz#s1-s1-s1-s3-s3-t1-k2-k8-k17-k1] |
− | * ticket: [https://jira.fd.io/browse/CSIT- | + | * ticket: [https://jira.fd.io/browse/CSIT-1953 CSIT-1950] |
− | ==== (M) | + | ==== (M) Lossy trials in nat udp mlx5 tests ==== |
− | * last update: | + | * last update: 2024-02-07 |
− | * work-to-fix: | + | * work-to-fix: hard |
− | * rca: | + | * rca: VPP counters suggest the packet is lost somewhere between TG on in-side [1] and VPP [2]. |
− | * test: | + | * test: It is affecting only cx7 with mlx5 driver (not e810cq with avf driver), only udp tests (not tcp or other), and interestingly both ASTF (both cps and tput for nat44ed) and STL (det44) traffic profiles. It does not affect corresponding ASTF tests with ip4base routing. |
− | * frequency: | + | * frequency: depends on scale, 100% on high scale tests. |
− | * testbed: | + | * testbed: 2n-icx, 2n-spr. |
− | * example: https://s3-logs.fd.io/vex-yul-rot-jenkins-1/csit-vpp-perf- | + | * example: [https://s3-logs.fd.io/vex-yul-rot-jenkins-1/csit-vpp-perf-ndrpdr-weekly-master-2n-spr/45/log.html.gz#s1-s1-s1-s2-s49-t2-k2-k14-k14] |
− | * ticket: [https://jira.fd.io/browse/CSIT- | + | * ticket: [https://jira.fd.io/browse/CSIT-1929 CSIT-1929] |
==== (L) 3n-icx: negative ipackets on TB38 AVF 4c l2patch ==== | ==== (L) 3n-icx: negative ipackets on TB38 AVF 4c l2patch ==== | ||
Line 89: | Line 112: | ||
* frequency: always | * frequency: always | ||
* testbed: 3n-icx (only TB38, never TB37) | * testbed: 3n-icx (only TB38, never TB37) | ||
− | * example: https://s3-logs.fd.io/vex-yul-rot-jenkins-1/csit-vpp-perf-mrr-daily-master-3n-icx/214/log.html.gz#s1-s1-s1-s5-s3-t3-k2-k9-k8-k13-k1-k2 | + | * example: [https://s3-logs.fd.io/vex-yul-rot-jenkins-1/csit-vpp-perf-mrr-daily-master-3n-icx/214/log.html.gz#s1-s1-s1-s5-s3-t3-k2-k9-k8-k13-k1-k2] |
* ticket: [https://jira.fd.io/browse/CSIT-1901 CSIT-1901] | * ticket: [https://jira.fd.io/browse/CSIT-1901 CSIT-1901] | ||
− | ==== (L) af_xdp mrr failures ==== | + | ==== (L) 2n-tx2: af_xdp mrr failures ==== |
− | * last update: 2023- | + | * last update: 2023-11-08 |
* work-to-fix: | * work-to-fix: | ||
− | * rca: | + | * rca: Some workers see no traffic, "error af_xdp_device_input_refill_db: rx poll() failed: Bad address" in show hardware. More examination needed. |
− | * test: | + | * test: ip4 and ip6, base and scale |
* frequency: more than 80% on a subset of cases, 100% on (multicore) 2n-tx2 | * frequency: more than 80% on a subset of cases, 100% on (multicore) 2n-tx2 | ||
− | * testbed: 2n-clx | + | * testbed: 2n-tx2; to a lesser extent also 2n-clx and 2n-icx, where just decreased performance (and failure in ndrpdr) is more likely outcome. |
− | * example: https://s3-logs.fd.io/vex-yul-rot-jenkins-1/csit-vpp-perf-mrr-daily-master-2n- | + | * example: [https://s3-logs.fd.io/vex-yul-rot-jenkins-1/csit-vpp-perf-mrr-daily-master-2n-spr/120/log.html.gz#s1-s1-s1-s2-s2-t2-k2-k10-k9-k14-k1-k1-k1-k1] |
* ticket: [https://jira.fd.io/browse/CSIT-1922 CSIT-1922] | * ticket: [https://jira.fd.io/browse/CSIT-1922 CSIT-1922] | ||
=== Not In Trending === | === Not In Trending === | ||
− | ==== (M) all | + | ==== (M) Combination of AVF and vhost drops all 9000B packets ==== |
− | * last update: | + | * last update: 2024-08-14 |
− | * work-to-fix: | + | * work-to-fix: medium |
− | * rca: | + | * rca: Buffer alloc error is seen, not sure why that happens. |
− | * test: | + | * test: 9000B vhost |
− | * frequency: | + | * frequency: 100% |
* testbed: all | * testbed: all | ||
− | * | + | * example: [https://s3-logs.fd.io/vex-yul-rot-jenkins-1/csit-vpp-perf-report-coverage-2406-2n-icx/33/log.html.gz#s1-s1-s1-s1-s1-t6-k3-k7-k1-k1-k1-k8-k14-k1-k1-k1-k1] |
− | + | * ticket: [https://jira.fd.io/browse/CSIT-1951 CSIT-1951] | |
− | * | + | * note: Sometimes VPP crashes, not sure if the cause is the same. |
− | + | ==== (M) 9000B tests with encap overhead and non-dpdk plugins see fragmented packets ==== | |
− | * last update: | + | * last update: 2024-08-14 |
− | * work-to-fix: | + | * work-to-fix: medium |
− | * test: 9000B | + | * rca: Some internal MTU is at 9000 (not 9200). More examination needed to see if the issue is in VPP or CSIT. |
− | * testbed: | + | * test: 9000B testcases for loadbalance, geneva, vxlan or SRv6 |
− | * | + | * frequency: 100% |
− | * ticket: [https://jira.fd.io/browse/CSIT- | + | * testbed: all |
+ | * example: [https://s3-logs.fd.io/vex-yul-rot-jenkins-1/csit-vpp-perf-report-coverage-2406-3n-alt/22/log.html.gz#s1-s1-s1-s1-s1-t7-k3-k7-k1-k1-k1-k8-k14-k2-k1-k1-k1-k1] | ||
+ | * ticket: [https://jira.fd.io/browse/CSIT-1950 CSIT-1950] | ||
+ | * note: Some tests drop packets (affects all tests), some tests fragment packets (does not fail MRR). | ||
− | ==== | + | ==== (M) IMIX 4c tests may fail PDR due to ~10% loss ==== |
− | * last update: | + | * last update: 2024-02-07 |
* work-to-fix: hard | * work-to-fix: hard | ||
− | * test: | + | * rca: Only seen in coverage tests so far, more data needed. |
− | * testbed: 2n- | + | * test: various high-performance, mostly mlx5 |
− | * | + | * frequency: <1% |
− | * ticket: [https://jira.fd.io/browse/CSIT- | + | * testbed: 2n-icx, 3n-icx, 3na-spr |
+ | * example: [https://s3-logs.fd.io/vex-yul-rot-jenkins-1/csit-dpdk-perf-report-coverage-2310-2n-icx/1/log.html.gz#s1-s1-s1-s3-t9-k2-k5-k16-k9] | ||
+ | * ticket: [https://jira.fd.io/browse/CSIT-1943 CSIT-1943] | ||
− | ==== | + | ==== (L) 3n-snr: Increased heap size in ipsec policy tests prevents VPP from starting ==== |
− | * last update: | + | * last update: 2024-08-14 |
− | * work-to-fix: | + | * work-to-fix: low |
− | * test: | + | * rca: Probably not enough huge pages. |
− | * testbed: | + | * test: ipsec policy large scale |
− | * | + | * frequency: 100% |
− | * ticket: [https://jira.fd.io/browse/CSIT- | + | * testbed: 3n-snr |
+ | * example: [https://s3-logs.fd.io/vex-yul-rot-jenkins-1/csit-vpp-perf-verify-master-3n-snr/131/log.html.gz#s1-s1-s1-s1-s1-t1-k2-k5-k1-k1-k1-k1] | ||
+ | * ticket: [https://jira.fd.io/browse/CSIT-1966 CSIT-1966] | ||
+ | * note: Not even in coverage. Found when investigating VPP-2121. | ||
− | + | ==== (L) Some tests have too long ramp-up trials ==== | |
− | * last update: | + | * last update: 2024-08-14 |
− | * work-to-fix: | + | * work-to-fix: low |
− | * test: | + | * rca: Ramp-up trial should have high enough rate to fit into session timeout. |
− | * testbed: | + | * test: NAT ASTF TPUT at large scale |
− | * | + | * frequency: 100% |
− | * ticket: [https://jira.fd.io/browse/CSIT- | + | * testbed: all |
+ | * example: [https://s3-logs.fd.io/vex-yul-rot-jenkins-1/csit-vpp-perf-report-iterative-2406-2n-zn2/57/log.html.gz#s1-s1-s1-s2-s19-t3-k2-k12-k14] | ||
+ | * ticket: [https://jira.fd.io/browse/CSIT-1961 CSIT-1961] | ||
+ | * note: We removed largest scale from most jobs, only few stragglers remain on coverage. | ||
− | ==== ( | + | ==== (L) Memif crashes VPP in container with jumbo frames ==== |
− | * last update: | + | * last update: 2024-08-14 |
− | * work-to-fix: | + | * work-to-fix: hard (bug in VPP, no easy access to logs) |
− | + | * test: any memif with 9000B | |
− | * test: | + | * testbed: all |
− | + | * examples: [https://s3-logs.fd.io/vex-yul-rot-jenkins-1/csit-vpp-perf-report-coverage-2406-2n-clx/25/log.html.gz#s1-s1-s1-s1-s1-t6-k3] | |
− | * testbed: | + | * ticket: [https://jira.fd.io/browse/VPP-2091 VPP-2091] |
− | * | + | |
− | * ticket: [https://jira.fd.io/browse/ | + | |
− | + | ||
− | ==== ( | + | ==== (L) l3fwd error in 200Ge2P1Cx7Veat-Mlx5 test with 9000B ==== |
− | * last update: | + | * last update: 2023-06-28 |
− | * work-to-fix: | + | * work-to-fix: medium |
− | + | * test: 9000B + Cx7 with DPDK DUT | |
− | * test: | + | * testbed: 2n-icx |
− | + | * examples: [https://s3-logs.fd.io/vex-yul-rot-jenkins-1/csit-dpdk-perf-report-coverage-2306-2n-icx/2/log.html.gz#s1-s1-s1-s4-t6-k2-k4] | |
− | * testbed: | + | * ticket: [https://jira.fd.io/browse/CSIT-1924 CSIT-1924] |
− | * | + | |
− | * ticket: [https://jira.fd.io/browse/CSIT- | + | |
==== (L) 2n-clx, 2n-icx: nat44ed cps 16M sessions scale fail ==== | ==== (L) 2n-clx, 2n-icx: nat44ed cps 16M sessions scale fail ==== | ||
− | * last update: | + | * last update: 2023-07-12 |
* work-to-fix: hard | * work-to-fix: hard | ||
− | * rca: | + | * rca: Ramp-up trial takes more than 5 minutes so sessions are timing out. |
* test: 64B-avf-ethip4tcp-nat44ed-h262144-p63-s16515072-cps-ndrpdr 1c 2c 4c, 64B-avf-ethip4udp-nat44ed-h262144-p63-s16515072-cps-ndrpdr 1c 2c 4c | * test: 64B-avf-ethip4tcp-nat44ed-h262144-p63-s16515072-cps-ndrpdr 1c 2c 4c, 64B-avf-ethip4udp-nat44ed-h262144-p63-s16515072-cps-ndrpdr 1c 2c 4c | ||
* frequency: always | * frequency: always | ||
* testbeds: 2n-skx, 2n-clx, 2n-icx | * testbeds: 2n-skx, 2n-clx, 2n-icx | ||
− | * example: [https://s3-logs.fd.io/vex-yul-rot-jenkins-1/csit-vpp-perf-report-coverage- | + | * example: [https://s3-logs.fd.io/vex-yul-rot-jenkins-1/csit-vpp-perf-report-coverage-2306-2n-clx/8/log.html.gz#s1-s1-s1-s1-s14-t2-k2-k15-k1] |
* ticket: [https://jira.fd.io/browse/CSIT-1799 CSIT-1799] | * ticket: [https://jira.fd.io/browse/CSIT-1799 CSIT-1799] | ||
==== (L) 2n-clx, 2n-icx: nat44det imix 1M sessions fails to create sessions ==== | ==== (L) 2n-clx, 2n-icx: nat44det imix 1M sessions fails to create sessions ==== | ||
− | * last update: | + | * last update: 2023-07-12 |
− | * work-to-fix: | + | * work-to-fix: medium |
− | * rca: | + | * rca: One possible cause is CSIT not counting ramp-up rate properly for IMIX (if multiple packets belong to the same session). |
* test: IMIX over 1M sessions bidir | * test: IMIX over 1M sessions bidir | ||
* frequency: always | * frequency: always | ||
* testbed: 2n-skx, 2n-clx, 2n-icx | * testbed: 2n-skx, 2n-clx, 2n-icx | ||
− | * example: [https://s3-logs.fd.io/vex-yul-rot-jenkins-1/csit-vpp-perf-report-coverage- | + | * example: [https://s3-logs.fd.io/vex-yul-rot-jenkins-1/csit-vpp-perf-report-coverage-2306-2n-clx/7/log.html.gz#s1-s1-s1-s1-s2-t4-k2-k11-k1-k2] |
* ticket: [https://jira.fd.io/browse/CSIT-1884 CSIT-1884] | * ticket: [https://jira.fd.io/browse/CSIT-1884 CSIT-1884] | ||
Line 202: | Line 231: | ||
=== In Trending === | === In Trending === | ||
− | ==== (H) | + | ==== (H) 3n-icxd: Various symptoms pointing to hardware (cable/nic/driver) issues ==== |
− | * last update: | + | * last update: 2024-08-14 |
+ | * work-to-fix: medium | ||
+ | * rca: Unknown hardware instability. Not sure if on SUT or TG side. | ||
+ | * test: any on 3n-icxd | ||
+ | * frequency: medium | ||
+ | * testbed: 3n-icxd | ||
+ | * example: [https://s3-logs.fd.io/vex-yul-rot-jenkins-1/csit-vpp-perf-report-iterative-2406-3n-icxd/58/log.html.gz#s1-s1-s1-s1-s18-t1-k2-k11-k9-k13-k7-k2] | ||
+ | * ticket: [https://jira.fd.io/browse/CSIT-1963 CSIT-1963] | ||
+ | * note: My be multiple issues, e.g. one hardware (loose cable) and one software (driver like in CSIT-1936). | ||
+ | |||
+ | ==== (M) 3n-icx hoststack: Udpquicscale tests sometimes fail with various symptoms ==== | ||
+ | |||
+ | * last update: 2024-08-14 | ||
* work-to-fix: hard | * work-to-fix: hard | ||
− | * rca: | + | * rca: Cause unclear a symptoms vary. Maybe memory corruption? |
− | * test: | + | * test: Udpquicscale |
* frequency: medium | * frequency: medium | ||
− | * testbed: | + | * testbed: 3n-icx |
− | * example: [https://s3-logs.fd.io/vex-yul-rot-jenkins-1/csit-vpp-perf- | + | * example: [https://s3-logs.fd.io/vex-yul-rot-jenkins-1/csit-vpp-perf-report-iterative-2406-3n-icx/110/log.html.gz#s1-s1-s1-s1-s7-t1-k3-k4-k1] |
− | * ticket: [https://jira.fd.io/browse/CSIT- | + | * ticket: [https://jira.fd.io/browse/CSIT-1962 CSIT-1962] |
− | * note: | + | * note: Not visible in trending as udpscale already suffers from CSIT-1935. |
− | ==== (M) | + | ==== (M) 3n-alt: high scale ipsec policy tests may crash VPP ==== |
− | * last update: | + | * last update: 2024-02-07 |
* work-to-fix: hard | * work-to-fix: hard | ||
− | * rca: | + | * rca: Vpp is crashing without creating core. |
− | * test: | + | * test: policy ipsec tests, large scale increases probability. |
− | * frequency: | + | * frequency: 15% and lower. |
− | * testbed: | + | * testbed: 3n-alt, also seen rarely on 3n-icx. |
− | * example: [https://s3-logs.fd.io/vex-yul-rot-jenkins-1/csit-vpp-perf- | + | * example: [https://s3-logs.fd.io/vex-yul-rot-jenkins-1/csit-vpp-perf-mrr-daily-master-3n-alt/357/log.html.gz#s1-s1-s1-s1-s15-t4-k3-k5-k1-k1] |
− | * ticket: [https://jira.fd.io/browse/CSIT- | + | * ticket: [https://jira.fd.io/browse/CSIT-1938 CSIT-1938] |
+ | |||
+ | ==== (M) 3nb-spr: Wireguardhw tests are likely to crash ==== | ||
+ | |||
+ | * last update: before 2024-08-14 | ||
+ | * work-to-fix: hard | ||
+ | * rca: More investigation needed. | ||
+ | * test: any wireguardhw | ||
+ | * frequency: low | ||
+ | * testbed: 3nb-spr | ||
+ | * examples: [https://s3-logs.fd.io/vex-yul-rot-jenkins-1/csit-vpp-perf-report-iterative-2406-3nb-spr/67/log.html.gz#s1-s1-s1-s3-s5] | ||
+ | * ticket: [https://jira.fd.io/browse/CSIT-1964 CSIT-1964] | ||
+ | * note: Symptoms are similar to CSIT-1938 or CSIT-1886, but both of those are frequent in high scale, this is not. | ||
==== (M) 3n-icx, 3n-snr: wireguard 100 and 1000 tunnels mlrsearch tests failing with 2c and 4c ==== | ==== (M) 3n-icx, 3n-snr: wireguard 100 and 1000 tunnels mlrsearch tests failing with 2c and 4c ==== | ||
Line 235: | Line 288: | ||
* examples: [https://s3-logs.fd.io/vex-yul-rot-jenkins-1/csit-vpp-perf-ndrpdr-weekly-master-3n-icx/56/log.html.gz#s1-s1-s1-s3-s8-t4 3n-icx] | * examples: [https://s3-logs.fd.io/vex-yul-rot-jenkins-1/csit-vpp-perf-ndrpdr-weekly-master-3n-icx/56/log.html.gz#s1-s1-s1-s3-s8-t4 3n-icx] | ||
* ticket: [https://jira.fd.io/browse/CSIT-1886 CSIT-1886] | * ticket: [https://jira.fd.io/browse/CSIT-1886 CSIT-1886] | ||
− | |||
− | |||
− | * last update: | + | ==== (M) e810cq sometimes reporting link down ==== |
+ | |||
+ | * last update: 2024-02-07 | ||
+ | * work-to-fix: hard | ||
+ | * rca: Mostly causing failure symptom of TRex complaining about link down. Probably also causes zero throughput in one direction in ASTF tests or even defice test failures. More frequent with more performant tests (L2) but seen affecting any test on occasion. | ||
+ | * test: Any that uses Intel-E810CQ NIC. | ||
+ | * frequency: <20% | ||
+ | * testbed: all with the NIC. | ||
+ | * examples: https://s3-logs.fd.io/vex-yul-rot-jenkins-1/csit-vpp-perf-ndrpdr-weekly-master-2n-spr/45/log.html.gz#s1-s1-s1-s2-s24-t1-k2-k12-k14 | ||
+ | * ticket: [https://jira.fd.io/browse/CSIT-1936 CSIT-1936] | ||
+ | |||
+ | === Not In Trending === | ||
+ | |||
+ | ==== (H) sw_interface_add_del_address: avf process node failed to reply in 5 seconds ==== | ||
+ | |||
+ | * last update: 2024-08-14 | ||
* work-to-fix: medium | * work-to-fix: medium | ||
− | * rca: | + | * rca: AVF processes API commands asynchronously, not prepared to receive multiple messages at once. |
− | * test: | + | * test: ipsec policy, but any other test using async PAPI processing may be affected. |
− | * frequency: high | + | * frequency: high on 3n-snr, less frequent on Xeon testbeds |
− | * testbed: | + | * testbed: all but with different frwequencies |
− | * example: [https://s3-logs.fd.io/vex-yul-rot-jenkins-1/csit- | + | * example: [https://s3-logs.fd.io/vex-yul-rot-jenkins-1/vpp-csit-verify-perf-master-ubuntu2204-x86_64-3n-snr/49/csit_current/0/log.html.gz#s1-s1-s1-s1-s1-t1-k3-k4-k1] |
− | * ticket: [https://jira.fd.io/browse/ | + | * ticket: [https://jira.fd.io/browse/VPP-2121 VPP-2121] |
+ | * note: Only coverage jobs are running ipsec policy with AFT driver. | ||
== Rare Failures == | == Rare Failures == | ||
Line 285: | Line 352: | ||
* note: This is mainly observed in iterative and coverage. It's very low frequency ~ 1 out of 100 | * note: This is mainly observed in iterative and coverage. It's very low frequency ~ 1 out of 100 | ||
− | ==== (L) | + | ==== (L) 2n-zn2: Geneve sometimes loses one direction of traffic ==== |
− | * last update: | + | * last update: 2024-08-14 |
* work-to-fix: hard | * work-to-fix: hard | ||
− | * rca: | + | * rca: More investigation needed to see the mechanism. |
− | * test: | + | * test: any geneve |
+ | * frequency: <1% | ||
+ | * testbed: 2n-zn2 | ||
+ | * example: [https://s3-logs.fd.io/vex-yul-rot-jenkins-1/csit-vpp-perf-report-iterative-2406-2n-zn2/54/log.html.gz#s1-s1-s1-s3-s1-t1-k2-k9-k14] | ||
+ | * ticket: [https://jira.fd.io/browse/CSIT-1960 CSIT-1960] | ||
+ | * note: Very rare, recently seen only as a failure in report iterative (not weekly trending) and in one run as MRR regression. | ||
+ | |||
+ | ==== (L) Rare VPP crash in nat avf tests ==== | ||
+ | |||
+ | * last update: 2024-08-14 | ||
+ | * work-to-fix: medium | ||
+ | * rca: clib_dlist_remove called by nat44_session_update_lru, but probably just a memory corruption symptom | ||
+ | * test: any NAT test with AVF | ||
* frequency: low | * frequency: low | ||
− | * testbed: | + | * testbed: any |
− | * example: [https://s3-logs.fd.io/vex-yul-rot-jenkins-1/csit-vpp-perf- | + | * example: [https://s3-logs.fd.io/vex-yul-rot-jenkins-1/csit-vpp-perf-report-iterative-2406-2n-clx/79/log.html.gz#s1-s1-s1-s2-s37-t2-k3-k4-k1] |
− | * ticket: [https://jira.fd.io/browse/CSIT- | + | * ticket: [https://jira.fd.io/browse/CSIT-1947 CSIT-1947] |
− | * note: | + | * note: More frequent in soak tests. |
+ | |||
+ | ==== (L) ipsec hwasync fails with large scale and multiple queues ==== | ||
+ | |||
+ | * last update: 2024-08-14 | ||
+ | * work-to-fix: hard | ||
+ | * test: ipsec hwasync | ||
+ | * frequency: low | ||
+ | * testbed: all with QAT | ||
+ | * example: [https://s3-logs.fd.io/vex-yul-rot-jenkins-1/csit-vpp-perf-report-iterative-2406-3n-icxd/58/log.html.gz#s1-s1-s1-s1-s1-t3-k3-k4-k1] | ||
+ | * ticket: [https://jira.fd.io/browse/CSIT-1946 CSIT-1946] | ||
+ | * note: Frequency decreased when CSIT changes RXQ ratio in 40824. | ||
==== (L) all testbeds: nat44det 4M and 16M scale 1 session not established ==== | ==== (L) all testbeds: nat44det 4M and 16M scale 1 session not established ==== | ||
Line 308: | Line 398: | ||
* ticket: [https://jira.fd.io/browse/CSIT-1795 CSIT-1795] | * ticket: [https://jira.fd.io/browse/CSIT-1795 CSIT-1795] | ||
− | ==== (L) | + | ==== (L) TRex may wrongly detect link bandwidth ==== |
− | * last update: | + | * last update: 2024-02-07 |
− | * work-to-fix: | + | * work-to-fix: hard |
− | * rca: | + | * rca: Quite rare failure affecting unpredictable tests. Perhaps a less severe symptom of CSIT-1936. |
− | * test: | + | * test: No obvious pattern due to low frequency |
− | * frequency: | + | * frequency: <0.4% |
− | * testbed: 3n- | + | * testbed: recently seen on 3n-tsh and 3nb-spr |
− | * example: https://s3-logs.fd.io/vex-yul-rot-jenkins-1/csit-vpp-perf- | + | * example: [https://s3-logs.fd.io/vex-yul-rot-jenkins-1/csit-vpp-perf-report-iterative-2310-3nb-spr/28/log.html.gz#s1-s1-s1-s1-s4-t1-k2-k13-k14] |
− | * ticket: [https://jira.fd.io/browse/CSIT- | + | * ticket: [https://jira.fd.io/browse/CSIT-1941 CSIT-1941] |
− | = | + | === Not In Trending === |
− | ==== ( | + | ==== (L) Occasional failure on 1518B CX5: Trex failed to send message ==== |
− | * last update: | + | * last update: 2024-08-14 |
− | * work-to-fix: | + | * work-to-fix: hard |
− | * rca: | + | * rca: More investigation needed. |
− | * test: | + | * test: Any 1518B on CX5, any driver. |
− | * frequency: | + | * frequency: low |
− | * testbed: | + | * testbed: 2n-clx |
− | * example: https://s3-logs.fd.io/vex-yul-rot-jenkins-1/csit-vpp-perf- | + | * example: [https://s3-logs.fd.io/vex-yul-rot-jenkins-1/csit-vpp-perf-report-coverage-2406-2n-clx/20/log.html.gz#s1-s1-s1-s1-s1-t4-k2-k9-k26-k11] |
− | * ticket: [https://jira.fd.io/browse/CSIT- | + | * ticket: [https://jira.fd.io/browse/CSIT-1965 CSIT-1965] |
− | * note: | + | * note: Only in coverage and 2n-clx has been decommissioned, but may appear if we move CX5 NICs to another testbed. |
− | = | + | = Past Failures = |
− | * last update: | + | ==== (H) 3na-spr, 2n-zn2: VPP fails to start in first test cases if dpdk/mlx5 ==== |
+ | |||
+ | * last update: 2024-02-07 | ||
* work-to-fix: medium | * work-to-fix: medium | ||
− | * rca: | + | * rca: DUT1 fails to boot up in first test case. If DUT2 is present, it fails to start in second test case. Other test cases in the run are unaffected. This looks like an infra issue, ansible cleanup is doing something wrong, hard to tell what. |
− | * test: | + | * test: First test case, unless it uses AVF driver. |
− | * frequency: | + | * frequency: 100% |
− | * testbed: 2n- | + | * testbed: 3na-spr, 2n-zn2 |
− | * example: https://s3-logs.fd.io/vex-yul-rot-jenkins-1/csit-vpp-perf- | + | * example: [https://s3-logs.fd.io/vex-yul-rot-jenkins-1/csit-vpp-perf-hoststack-daily-master-3na-spr/139/log.html.gz#s1-s1-s1-s1-s1-t1-k2-k3-k2-k5-k1-k1-k1-k1] |
− | * ticket: [https://jira.fd.io/browse/CSIT- | + | * ticket: [https://jira.fd.io/browse/CSIT-1939 CSIT-1939] |
− | + | ||
− | ==== ( | + | ==== (H) 2n-icx: NFV density VPP does not start in container ==== |
− | * last update: 2023- | + | * last update: before 2023-01-31 |
− | * work-to-fix: | + | * work-to-fix: hard |
− | * rca: | + | * rca: |
− | * test: | + | * test: all subsequent |
− | * frequency: | + | * frequency: medium |
* testbed: 2n-icx | * testbed: 2n-icx | ||
− | * example: https://s3-logs.fd.io/vex-yul-rot-jenkins-1/csit-vpp-perf- | + | * example: [https://s3-logs.fd.io/vex-yul-rot-jenkins-1/csit-vpp-perf-mrr-weekly-master-2n-icx/57/log.html.gz 2n-icx mrr], [https://s3-logs.fd.io/vex-yul-rot-jenkins-1/csit-vpp-perf-ndrpdr-weekly-master-2n-icx/48/log.html.gz#s1-s1-s1-s5-s8-t1 2n-icx ndrpdr] |
− | * ticket: [https://jira.fd.io/browse/CSIT- | + | * ticket: [https://jira.fd.io/browse/CSIT-1881 CSIT-1881] |
− | * note: | + | * note: Once VPP breaks, all subsequent tests fail. Even all subsequent builds will be failing until Peter makes TB working again. Although it's failing with medium frequency when it happens it breaks all subsequent builds on the TB therefore [H] priority. |
− | ==== (M) | + | ==== (M) 3n-icx, 3n-snr: 1518B IPsec packets not passing ==== |
− | * last update: 2023- | + | * last update: before 2023-01-31 |
− | * work-to-fix: | + | * work-to-fix: hard |
− | * rca: | + | * rca: |
− | * test: | + | * test: all AVF crypto |
− | * frequency: | + | * frequency: low |
− | * testbed: 3n-icx | + | * testbed: 3n-skx, 3n-icx, 3n-snr |
− | * example: https://s3-logs.fd.io/vex-yul-rot-jenkins-1/csit-vpp-perf- | + | * example: [https://s3-logs.fd.io/vex-yul-rot-jenkins-1/csit-vpp-perf-mrr-daily-master-3n-icx/197/log.html.gz#s1-s1-s1-s1-s4-t1 3n-icx daily], [https://s3-logs.fd.io/vex-yul-rot-jenkins-1/csit-vpp-perf-mrr-daily-master-3n-snr/32/log.html.gz#s1-s1-s1-s1-s4-t1 3n-snr], [https://s3-logs.fd.io/vex-yul-rot-jenkins-1/csit-vpp-perf-ndrpdr-weekly-master-3n-icx/57/log.html.gz#s1-s1-s1-s1-s4-t1 3n-icx weekly] |
− | + | * ticket: [https://jira.fd.io/browse/CSIT-1827 CSIT-1827] | |
− | * | + | |
− | ==== (L) | + | ==== (L) all testbeds: vpp create avf interface failure in multi-core configs ==== |
− | * last update: 2023- | + | * last update: 2023-02-06 |
* work-to-fix: hard | * work-to-fix: hard | ||
− | * rca: | + | * rca: issue in Intel FVL driver |
− | * test: | + | * test: multicore AVF |
− | * frequency: | + | * frequency: low |
− | * testbed: | + | * testbed: all testbeds |
− | * example: [https://s3-logs.fd.io/vex-yul-rot-jenkins-1/csit- | + | * example: [https://s3-logs.fd.io/vex-yul-rot-jenkins-1/csit-vpp-perf-mrr-daily-master-2n-clx/1257/log.html.gz#s1-s1-s1-s5-s24-t2 2n-clx], [https://s3-logs.fd.io/vex-yul-rot-jenkins-1/csit-vpp-perf-mrr-daily-master-3n-icx/197/log.html.gz#s1-s1-s1-s5-s1-t3 3n-icx] |
− | * ticket: [https://jira.fd.io/browse/CSIT- | + | * ticket: [https://jira.fd.io/browse/CSIT-1782 CSIT-1782] |
− | * note: | + | * note: A long standing issue without a final permanent fix. |
Latest revision as of 14:33, 14 August 2024
Contents
- 1 CSIT Test Failure Clasification
- 2 CSIT Test Fixing Priorities
- 3 Current Failures
- 3.1 Deterministic Failures
- 3.1.1 In Trending
- 3.1.1.1 (H) 3n spr: Unusable performance of ipsec tests with SHA_256_128
- 3.1.1.2 (H) 3nb-spr hoststack: interface not up after first test
- 3.1.1.3 (H) Zero traffic reported in udpquic tests
- 3.1.1.4 (M) DPDK 23.03 testpmd startup fails on some testbeds
- 3.1.1.5 (M) 2n-spr: zero traffic on cx7 rdma
- 3.1.1.6 (M) 3n-icx 3nb-spr: Failed to enable GTPU offload RX
- 3.1.1.7 (M) Lossy trials in nat udp mlx5 tests
- 3.1.1.8 (L) 3n-icx: negative ipackets on TB38 AVF 4c l2patch
- 3.1.1.9 (L) 2n-tx2: af_xdp mrr failures
- 3.1.2 Not In Trending
- 3.1.2.1 (M) Combination of AVF and vhost drops all 9000B packets
- 3.1.2.2 (M) 9000B tests with encap overhead and non-dpdk plugins see fragmented packets
- 3.1.2.3 (M) IMIX 4c tests may fail PDR due to ~10% loss
- 3.1.2.4 (L) 3n-snr: Increased heap size in ipsec policy tests prevents VPP from starting
- 3.1.2.5 (L) Some tests have too long ramp-up trials
- 3.1.2.6 (L) Memif crashes VPP in container with jumbo frames
- 3.1.2.7 (L) l3fwd error in 200Ge2P1Cx7Veat-Mlx5 test with 9000B
- 3.1.2.8 (L) 2n-clx, 2n-icx: nat44ed cps 16M sessions scale fail
- 3.1.2.9 (L) 2n-clx, 2n-icx: nat44det imix 1M sessions fails to create sessions
- 3.1.1 In Trending
- 3.2 Occasional Failures
- 3.2.1 In Trending
- 3.2.1.1 (H) 3n-icxd: Various symptoms pointing to hardware (cable/nic/driver) issues
- 3.2.1.2 (M) 3n-icx hoststack: Udpquicscale tests sometimes fail with various symptoms
- 3.2.1.3 (M) 3n-alt: high scale ipsec policy tests may crash VPP
- 3.2.1.4 (M) 3nb-spr: Wireguardhw tests are likely to crash
- 3.2.1.5 (M) 3n-icx, 3n-snr: wireguard 100 and 1000 tunnels mlrsearch tests failing with 2c and 4c
- 3.2.1.6 (M) e810cq sometimes reporting link down
- 3.2.2 Not In Trending
- 3.2.1 In Trending
- 3.3 Rare Failures
- 3.3.1 In Trending
- 3.3.1.1 (M) 3n-icx, 3n-snr: 1518B IPsec packets not passing
- 3.3.1.2 (M) all testbeds: mlrsearch fails to find NDR rate
- 3.3.1.3 (M) all testbeds: AF_XDP mlrsearch fails to find NDR rate
- 3.3.1.4 (L) 2n-zn2: Geneve sometimes loses one direction of traffic
- 3.3.1.5 (L) Rare VPP crash in nat avf tests
- 3.3.1.6 (L) ipsec hwasync fails with large scale and multiple queues
- 3.3.1.7 (L) all testbeds: nat44det 4M and 16M scale 1 session not established
- 3.3.1.8 (L) TRex may wrongly detect link bandwidth
- 3.3.2 Not In Trending
- 3.3.1 In Trending
- 3.1 Deterministic Failures
- 4 Past Failures
CSIT Test Failure Clasification
All known CSIT failures grouped and listed in the following order:
- Always failing followed by sometimes failing.
- Always failing tests:
- Most common use cases followed by less common.
- Sometimes failing tests:
- Most frequently failing followed by less frequently failing.
- High frequency 50%-100%
- medium frequency 10%-50%
- low frequency 0%-10%.
- Within each sub-group: most common use cases followed by less common.
- Most frequently failing followed by less frequently failing.
CSIT Test Fixing Priorities
Test fixing work priorities defined as follows:
- (H)igh priority, most common use cases and most common test code.
- (M)edium priority, specific HW and pervasive test code issue.
- (L)ow priority, corner cases and external dependencies.
Current Failures
Deterministic Failures
In Trending
(H) 3n spr: Unusable performance of ipsec tests with SHA_256_128
- last update: 2024-08-14
- work-to-fix: low (if you are Damjan)
- rca: It seems compiler emits wrong instructions, VPP build system needs to be fixed.
- test: Three new ipsec tests that use SHA_256_128 as integrity algorithm.
- frequency: 50%
- testbed: 3na-spr, 3nb-spr
- example: [1]
- ticket: VPP-2118
- note: Other Xeon testbeds are also affected, but performance is not as bad to fail NDR. ARM is not affected at all.
(H) 3nb-spr hoststack: interface not up after first test
- last update: 2024-02-07
- work-to-fix: medium
- rca: After first test, HundredGigabitEthernetab/0/0 never goes up within the run. Not sure which part f test setup is missing, the tests do work correctly on other testbeds.
- test: All subsequent tests.
- frequency: 100%
- testbed: 3nb-apr
- example: [2]
- ticket: CSIT-1942
(H) Zero traffic reported in udpquic tests
- last update: 2024-02-07
- work-to-fix: medium
- rca: There are errors when closing sessions. The current CSIT logic happens to report this as a passing test with zero traffic, which is wrong.
- test: All tests udpquic tests
- frequency: 100%
- testbed: all running the tests
- example: [3]
- ticket: CSIT-1935
(M) DPDK 23.03 testpmd startup fails on some testbeds
- last update: 2023-11-06
- work-to-fix: medium
- rca: The DUT-DUT link sometimes does not go up. The same consequences as CSIT-1848 but affects more testbed+NIC combinations. Can be fixed by a different startup procedure (better detection before for restart).
- test: Testpmd (no vpp). Around half of tested+NIC combinations are affected.
- frequency: Low, ~1%, as in most testbeds the link does go up.
- testbed: multiple
- example: [4]
- ticket: CSIT-1904
(M) 2n-spr: zero traffic on cx7 rdma
- last update: 2023-06-22
- work-to-fix: medium
- rca: VPP reports "tx completion errors", more investigation ongoing.
- test: All tests on 2n-spr with 200Ge2P1Cx7Veat NIC and RDMA driver.
- frequency: always (since 2n-spr was set up)
- testbed: 2n-spr
- example: [5]
- ticket: CSIT-1906
- note: Also would affect 3n-alt with mlxc6 and rdma. Will probably be made invisible by removing rdma (except mlxc5) from jobspecs.
(M) 3n-icx 3nb-spr: Failed to enable GTPU offload RX
- last update: 2024-08-14
- work-to-fix: low
- rca: Retval is -1. More examination is needed to understand why.
- test: any gtpuhw
- frequency: 100%
- testbed: all
- example: [6]
- ticket: CSIT-1950
(M) Lossy trials in nat udp mlx5 tests
- last update: 2024-02-07
- work-to-fix: hard
- rca: VPP counters suggest the packet is lost somewhere between TG on in-side [1] and VPP [2].
- test: It is affecting only cx7 with mlx5 driver (not e810cq with avf driver), only udp tests (not tcp or other), and interestingly both ASTF (both cps and tput for nat44ed) and STL (det44) traffic profiles. It does not affect corresponding ASTF tests with ip4base routing.
- frequency: depends on scale, 100% on high scale tests.
- testbed: 2n-icx, 2n-spr.
- example: [7]
- ticket: CSIT-1929
(L) 3n-icx: negative ipackets on TB38 AVF 4c l2patch
- last update: 2023-04-19
- work-to-fix:
- rca:
- test: TB38 AVF 4c e810cq, earlier l2patch nowadays eth-l2xcbase
- frequency: always
- testbed: 3n-icx (only TB38, never TB37)
- example: [8]
- ticket: CSIT-1901
(L) 2n-tx2: af_xdp mrr failures
- last update: 2023-11-08
- work-to-fix:
- rca: Some workers see no traffic, "error af_xdp_device_input_refill_db: rx poll() failed: Bad address" in show hardware. More examination needed.
- test: ip4 and ip6, base and scale
- frequency: more than 80% on a subset of cases, 100% on (multicore) 2n-tx2
- testbed: 2n-tx2; to a lesser extent also 2n-clx and 2n-icx, where just decreased performance (and failure in ndrpdr) is more likely outcome.
- example: [9]
- ticket: CSIT-1922
Not In Trending
(M) Combination of AVF and vhost drops all 9000B packets
- last update: 2024-08-14
- work-to-fix: medium
- rca: Buffer alloc error is seen, not sure why that happens.
- test: 9000B vhost
- frequency: 100%
- testbed: all
- example: [10]
- ticket: CSIT-1951
- note: Sometimes VPP crashes, not sure if the cause is the same.
(M) 9000B tests with encap overhead and non-dpdk plugins see fragmented packets
- last update: 2024-08-14
- work-to-fix: medium
- rca: Some internal MTU is at 9000 (not 9200). More examination needed to see if the issue is in VPP or CSIT.
- test: 9000B testcases for loadbalance, geneva, vxlan or SRv6
- frequency: 100%
- testbed: all
- example: [11]
- ticket: CSIT-1950
- note: Some tests drop packets (affects all tests), some tests fragment packets (does not fail MRR).
(M) IMIX 4c tests may fail PDR due to ~10% loss
- last update: 2024-02-07
- work-to-fix: hard
- rca: Only seen in coverage tests so far, more data needed.
- test: various high-performance, mostly mlx5
- frequency: <1%
- testbed: 2n-icx, 3n-icx, 3na-spr
- example: [12]
- ticket: CSIT-1943
(L) 3n-snr: Increased heap size in ipsec policy tests prevents VPP from starting
- last update: 2024-08-14
- work-to-fix: low
- rca: Probably not enough huge pages.
- test: ipsec policy large scale
- frequency: 100%
- testbed: 3n-snr
- example: [13]
- ticket: CSIT-1966
- note: Not even in coverage. Found when investigating VPP-2121.
(L) Some tests have too long ramp-up trials
- last update: 2024-08-14
- work-to-fix: low
- rca: Ramp-up trial should have high enough rate to fit into session timeout.
- test: NAT ASTF TPUT at large scale
- frequency: 100%
- testbed: all
- example: [14]
- ticket: CSIT-1961
- note: We removed largest scale from most jobs, only few stragglers remain on coverage.
(L) Memif crashes VPP in container with jumbo frames
- last update: 2024-08-14
- work-to-fix: hard (bug in VPP, no easy access to logs)
- test: any memif with 9000B
- testbed: all
- examples: [15]
- ticket: VPP-2091
(L) l3fwd error in 200Ge2P1Cx7Veat-Mlx5 test with 9000B
- last update: 2023-06-28
- work-to-fix: medium
- test: 9000B + Cx7 with DPDK DUT
- testbed: 2n-icx
- examples: [16]
- ticket: CSIT-1924
(L) 2n-clx, 2n-icx: nat44ed cps 16M sessions scale fail
- last update: 2023-07-12
- work-to-fix: hard
- rca: Ramp-up trial takes more than 5 minutes so sessions are timing out.
- test: 64B-avf-ethip4tcp-nat44ed-h262144-p63-s16515072-cps-ndrpdr 1c 2c 4c, 64B-avf-ethip4udp-nat44ed-h262144-p63-s16515072-cps-ndrpdr 1c 2c 4c
- frequency: always
- testbeds: 2n-skx, 2n-clx, 2n-icx
- example: [17]
- ticket: CSIT-1799
(L) 2n-clx, 2n-icx: nat44det imix 1M sessions fails to create sessions
- last update: 2023-07-12
- work-to-fix: medium
- rca: One possible cause is CSIT not counting ramp-up rate properly for IMIX (if multiple packets belong to the same session).
- test: IMIX over 1M sessions bidir
- frequency: always
- testbed: 2n-skx, 2n-clx, 2n-icx
- example: [18]
- ticket: CSIT-1884
Occasional Failures
In Trending
(H) 3n-icxd: Various symptoms pointing to hardware (cable/nic/driver) issues
- last update: 2024-08-14
- work-to-fix: medium
- rca: Unknown hardware instability. Not sure if on SUT or TG side.
- test: any on 3n-icxd
- frequency: medium
- testbed: 3n-icxd
- example: [19]
- ticket: CSIT-1963
- note: My be multiple issues, e.g. one hardware (loose cable) and one software (driver like in CSIT-1936).
(M) 3n-icx hoststack: Udpquicscale tests sometimes fail with various symptoms
- last update: 2024-08-14
- work-to-fix: hard
- rca: Cause unclear a symptoms vary. Maybe memory corruption?
- test: Udpquicscale
- frequency: medium
- testbed: 3n-icx
- example: [20]
- ticket: CSIT-1962
- note: Not visible in trending as udpscale already suffers from CSIT-1935.
(M) 3n-alt: high scale ipsec policy tests may crash VPP
- last update: 2024-02-07
- work-to-fix: hard
- rca: Vpp is crashing without creating core.
- test: policy ipsec tests, large scale increases probability.
- frequency: 15% and lower.
- testbed: 3n-alt, also seen rarely on 3n-icx.
- example: [21]
- ticket: CSIT-1938
(M) 3nb-spr: Wireguardhw tests are likely to crash
- last update: before 2024-08-14
- work-to-fix: hard
- rca: More investigation needed.
- test: any wireguardhw
- frequency: low
- testbed: 3nb-spr
- examples: [22]
- ticket: CSIT-1964
- note: Symptoms are similar to CSIT-1938 or CSIT-1886, but both of those are frequent in high scale, this is not.
(M) 3n-icx, 3n-snr: wireguard 100 and 1000 tunnels mlrsearch tests failing with 2c and 4c
- last update: before 2023-01-31
- work-to-fix: easy
- rca:
- test: wireguard 100 tunnels and more
- frequency: high
- testbed: 3n-icx, 3n-snr
- examples: 3n-icx
- ticket: CSIT-1886
(M) e810cq sometimes reporting link down
- last update: 2024-02-07
- work-to-fix: hard
- rca: Mostly causing failure symptom of TRex complaining about link down. Probably also causes zero throughput in one direction in ASTF tests or even defice test failures. More frequent with more performant tests (L2) but seen affecting any test on occasion.
- test: Any that uses Intel-E810CQ NIC.
- frequency: <20%
- testbed: all with the NIC.
- examples: https://s3-logs.fd.io/vex-yul-rot-jenkins-1/csit-vpp-perf-ndrpdr-weekly-master-2n-spr/45/log.html.gz#s1-s1-s1-s2-s24-t1-k2-k12-k14
- ticket: CSIT-1936
Not In Trending
(H) sw_interface_add_del_address: avf process node failed to reply in 5 seconds
- last update: 2024-08-14
- work-to-fix: medium
- rca: AVF processes API commands asynchronously, not prepared to receive multiple messages at once.
- test: ipsec policy, but any other test using async PAPI processing may be affected.
- frequency: high on 3n-snr, less frequent on Xeon testbeds
- testbed: all but with different frwequencies
- example: [23]
- ticket: VPP-2121
- note: Only coverage jobs are running ipsec policy with AFT driver.
Rare Failures
In Trending
(M) 3n-icx, 3n-snr: 1518B IPsec packets not passing
- last update: before 2023-01-31
- work-to-fix: hard
- rca:
- test: all AVF crypto
- frequency: low
- testbed: 3n-skx, 3n-icx, 3n-snr
- example: 3n-icx daily, 3n-snr, 3n-icx weekly
- ticket: CSIT-1827
(M) all testbeds: mlrsearch fails to find NDR rate
- last update: before 2023-06-22
- work-to-fix: hard
- rca: On 3n-tsh, the symptom is TRex reporting ierrors, only in one direction. Other testbeds may have a different symptom, but failures there are less frequent.
- test: Crypto, Ip4, L2, Srv6, Vm Vhost (all packet sizes, all core configurations affected)
- frequency: low
- testbed: 3n-tsh, 3n-alt, 2n-clx
- example: [24]
- ticket: CSIT-1804
(M) all testbeds: AF_XDP mlrsearch fails to find NDR rate
- last update: before 2023-01-31
- work-to-fix: hard
- rca:
- test: af-xdp multicore tests
- frequency: low
- testbed: 2n-clx, 2n-skx, 2n-tx2, 2n-icx
- example: 2n-skx, 2n-clx
- ticket: CSIT-1802
- note: This is mainly observed in iterative and coverage. It's very low frequency ~ 1 out of 100
(L) 2n-zn2: Geneve sometimes loses one direction of traffic
- last update: 2024-08-14
- work-to-fix: hard
- rca: More investigation needed to see the mechanism.
- test: any geneve
- frequency: <1%
- testbed: 2n-zn2
- example: [25]
- ticket: CSIT-1960
- note: Very rare, recently seen only as a failure in report iterative (not weekly trending) and in one run as MRR regression.
(L) Rare VPP crash in nat avf tests
- last update: 2024-08-14
- work-to-fix: medium
- rca: clib_dlist_remove called by nat44_session_update_lru, but probably just a memory corruption symptom
- test: any NAT test with AVF
- frequency: low
- testbed: any
- example: [26]
- ticket: CSIT-1947
- note: More frequent in soak tests.
(L) ipsec hwasync fails with large scale and multiple queues
- last update: 2024-08-14
- work-to-fix: hard
- test: ipsec hwasync
- frequency: low
- testbed: all with QAT
- example: [27]
- ticket: CSIT-1946
- note: Frequency decreased when CSIT changes RXQ ratio in 40824.
(L) all testbeds: nat44det 4M and 16M scale 1 session not established
- last update: 2023-02-14
- work-to-fix: hard
- rca: unknown
- test: nat44det udp 4m and 16m (64k is ok, 1m can fail but rarely than bigger scales)
- frequency: low
- testbed: 2n-zn2, 2n-skx, 2n-icx, 2n-clx
- example: 2n-zn2, 2n-clx
- ticket: CSIT-1795
(L) TRex may wrongly detect link bandwidth
- last update: 2024-02-07
- work-to-fix: hard
- rca: Quite rare failure affecting unpredictable tests. Perhaps a less severe symptom of CSIT-1936.
- test: No obvious pattern due to low frequency
- frequency: <0.4%
- testbed: recently seen on 3n-tsh and 3nb-spr
- example: [28]
- ticket: CSIT-1941
Not In Trending
(L) Occasional failure on 1518B CX5: Trex failed to send message
- last update: 2024-08-14
- work-to-fix: hard
- rca: More investigation needed.
- test: Any 1518B on CX5, any driver.
- frequency: low
- testbed: 2n-clx
- example: [29]
- ticket: CSIT-1965
- note: Only in coverage and 2n-clx has been decommissioned, but may appear if we move CX5 NICs to another testbed.
Past Failures
(H) 3na-spr, 2n-zn2: VPP fails to start in first test cases if dpdk/mlx5
- last update: 2024-02-07
- work-to-fix: medium
- rca: DUT1 fails to boot up in first test case. If DUT2 is present, it fails to start in second test case. Other test cases in the run are unaffected. This looks like an infra issue, ansible cleanup is doing something wrong, hard to tell what.
- test: First test case, unless it uses AVF driver.
- frequency: 100%
- testbed: 3na-spr, 2n-zn2
- example: [30]
- ticket: CSIT-1939
(H) 2n-icx: NFV density VPP does not start in container
- last update: before 2023-01-31
- work-to-fix: hard
- rca:
- test: all subsequent
- frequency: medium
- testbed: 2n-icx
- example: 2n-icx mrr, 2n-icx ndrpdr
- ticket: CSIT-1881
- note: Once VPP breaks, all subsequent tests fail. Even all subsequent builds will be failing until Peter makes TB working again. Although it's failing with medium frequency when it happens it breaks all subsequent builds on the TB therefore [H] priority.
(M) 3n-icx, 3n-snr: 1518B IPsec packets not passing
- last update: before 2023-01-31
- work-to-fix: hard
- rca:
- test: all AVF crypto
- frequency: low
- testbed: 3n-skx, 3n-icx, 3n-snr
- example: 3n-icx daily, 3n-snr, 3n-icx weekly
- ticket: CSIT-1827