|
|
(16 intermediate revisions by 4 users not shown) |
Line 1: |
Line 1: |
− | == FD.io CSIT Lab Extension - LLD Draft ==
| + | This page has been deprecated. Content has been moved to [[CSIT/Testbeds:_Xeon_Skx,_Arm,_Atom. | FD.io CSIT testbeds - Xeon Skylake, Arm, Atom]]. |
− | | + | |
− | This is a (proposed) low-level design for the extensions of FD.io CSIT lab to accommodate the new Intel Xeon Skylake, Arm AArch64 and Atom devices. The current version is available on [https://wiki.fd.io/view/CSIT/fdio_csit_lab_ext_lld_draft CSIT wiki]. | + | |
− | | + | |
− | == Testbeds Overview ==
| + | |
− | | + | |
− | === Testbeds Type Breakdown ===
| + | |
− | | + | |
− | <pre>
| + | |
− | #. CSIT_tb. Purpose. SUT. TG. #tb. #SUTs. #TGs. #skx_node.
| + | |
− | 1. 1-node Xeon. func. skx. n/a. 2. 2. 0. 2.
| + | |
− | 2. 2-node Xeon. perf. skx. skx. 4. 4. 4. 8.
| + | |
− | 3. 3-node Xeon. perf. skx. skx. 2. 4. 2. 6.
| + | |
− | 4. tcp-l47. tcp-stack. skx. ps1. 1. 1. 1. 1.
| + | |
− | 5. atom-netgate. perf+func. net. skx. 1. 3. 1. 1.
| + | |
− | 6. aarch64. perf+func. arm. skx. >1. >1. 2. 2.
| + | |
− | Total skx_node: 20.
| + | |
− | </pre>
| + | |
− | | + | |
− | === 1-Node Xeon Testbeds ===
| + | |
− | | + | |
− | One 1-node Xeon testbed for VPP_Device tests is built using one SUT (Type-6 server), with NIC ports connected back-to-back.
| + | |
− | | + | |
− | === 2-Node Xeon Testbeds ===
| + | |
− | | + | |
− | Four 2-node Xeon testbeds (are expected to be built|are built), with each testbed using one SUTs (Type-1 server) and one TG (Type-2 server) connected back-to-back. NIC cards placement into slots and NIC ports connectivity is following the testbed specification included in next sections.
| + | |
− | | + | |
− | === 3-Node Xeon Testbeds ===
| + | |
− | | + | |
− | Two 3-node Xeon testbeds (are expected to be built|are built), with each testbed using two SUTs (Type-1 server) and one TG (Type-2 server) connected in full-mesh triangle. NIC cards placement into slots and NIC ports connectivity is following the testbed specification included in next sections.
| + | |
− | | + | |
− | === Arm Testbeds ===
| + | |
− | | + | |
− | One 3-node Huawei testbeds (are expected to be built|are built), with each testbed using two SUTs (Type-3 server) and one TG (Type-2 server) connected in full-mesh triangle.
| + | |
− | | + | |
− | One 3-node Marvell testbeds (are expected to be built|are built), with each testbed using two SUTs (Type-4 server) and one TG (Type-2 server) connected in full-mesh triangle.
| + | |
− | | + | |
− | === TCP/IP and L47 Testbeds ===
| + | |
− | | + | |
− | One 2-node Ixia PS One and Xeon server testbed, for TCP/IP host stack tests.
| + | |
− | | + | |
− | === Atom Testbeds ===
| + | |
− | | + | |
− | One 3-node Atom (Netgate based) testbed is built consisting of three SUTs (Type-5 Netgate device.) NIC cards placement into slots and NIC ports connectivity is following the testbed specification included in the next section.
| + | |
− | | + | |
− | == Inventory ==
| + | |
− | | + | |
− | === Appliances ===
| + | |
− | | + | |
− | <pre>
| + | |
− | 1. Ixia PerfectStorm One Appliance
| + | |
− | - 1 * PS10GE4NG
| + | |
− | - Chassis: PS10GE4NG.
| + | |
− | - Motherboard: SuperMicro X11DPG-QT.
| + | |
− | - Processors: Quad-Core, Intel Processor.
| + | |
− | - HW accelerators: FPGA offload.
| + | |
− | - RAM Memory: 64GB.
| + | |
− | - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
| + | |
− | - Physical Interfaces: 4 * 10GE SFP+.
| + | |
− | - Operating System: Native IxOS.
| + | |
− | </pre>
| + | |
− | | + | |
− | === Servers ===
| + | |
− | | + | |
− | <pre>
| + | |
− | 1. Intel Xeon servers:
| + | |
− | - 20 * SuperMicro SYS-7049GP-TRT with Xeon Skylake processors.
| + | |
− | - Chassis: SuperMicro SYS-7049GP-TRT.
| + | |
− | - Motherboard: SuperMicro X11DPG-QT.
| + | |
− | - Processors: 2* Intel Platinum 8180 2.3 GHz.
| + | |
− | - RAM Memory: 16* 16GB DDR4-2666MHz.
| + | |
− | - Disks: 2* 1.6TB 6G SATA SSD.
| + | |
− | 2. Arm Cortex A-72 servers
| + | |
− | - 2 * Huawei TaiShan 2280.
| + | |
− | - Chassis: Huawei TaiShan 2280.
| + | |
− | - Processors: 1* hip07-d05 ~ 64* Arm Cortex-A72.
| + | |
− | - RAM Memory: 8* 16GB DDR4-2400MT/s.
| + | |
− | - Disks: 1* 4TB SATA HDD.
| + | |
− | - 3 * MACCHIATObin
| + | |
− | - Chassis: MACCHIATObin.
| + | |
− | - Processors: 1* Armada 8040 ~ 4* Arm Cortex-A72.
| + | |
− | - RAM Memory: 1* 16GB DDR4.
| + | |
− | - Disks: 1* 128GB(?) SATA SDD.
| + | |
− | 3. Intel Atom servers with Rangely processors.
| + | |
− | - 3 * Netgate XG-2758-1u
| + | |
− | - Chassis: Netgate XG-2758-1u
| + | |
− | - Processors: 1* Rangely (Atom) C2758 2.4 GHz
| + | |
− | - RAM Memory: 16GB ECC
| + | |
− | - Disks: 150 GB
| + | |
− | </pre>
| + | |
− | | + | |
− | === Network Interface Cards ===
| + | |
− | | + | |
− | <pre>
| + | |
− | 1. 10GE NICs
| + | |
− | - 30 * X710-DA4.
| + | |
− | - 6 * X710-DA2.
| + | |
− | - 6 * X520-DA2.
| + | |
− | 2. 25GE NICs
| + | |
− | - 20 * XXV710-DA2.
| + | |
− | 3. 40GE NICs
| + | |
− | - 2 * XL710-QDA2.
| + | |
− | 4. 100GE NICs
| + | |
− | - none.
| + | |
− | </pre>
| + | |
− | | + | |
− | === Pluggables and Cables ===
| + | |
− | | + | |
− | Pluggables:
| + | |
− | | + | |
− | <pre>
| + | |
− | 1. 10GE SFP+
| + | |
− | - 80 * Intel Ethernet SFP+ SR.
| + | |
− | 2. 25GE SFP28
| + | |
− | - None?
| + | |
− | 3. 40GE QSFP+
| + | |
− | - 20 * Intel® Ethernet QSFP+ Twinaxial Cable, 5 meters.
| + | |
− | 4. 100GE
| + | |
− | - None?
| + | |
− | </pre>
| + | |
− | | + | |
− | Standalone cables:
| + | |
− | | + | |
− | <pre>
| + | |
− | 1. 10GE
| + | |
− | - None?
| + | |
− | 2. 25GE
| + | |
− | - None?
| + | |
− | 3. 40GE
| + | |
− | - None?
| + | |
− | 4. 100GE
| + | |
− | - None?
| + | |
− | </pre>
| + | |
− | | + | |
− | === Other Network Cards ===
| + | |
− | | + | |
− | Any QATs?
| + | |
− | | + | |
− | == Installation Status ==
| + | |
− | | + | |
− | Lab installation status is tracked by LF IT team in [https://docs.google.com/document/d/16TdvGC73wuNQjkP355MTXRckv7yqnaxJkWwX7G7izEo/edit?ts=5b10411b#heading=h.dprb64shku8u FD.io Server Status].
| + | |
− | | + | |
− | == Server/Device Management and Naming ==
| + | |
− | | + | |
− | === Server Management Requirements ===
| + | |
− | | + | |
− | Total of 20 SM SYS-7049GP-TRT servers are made available for FD.IO CSIT testbed.
| + | |
− | For management purposes, each server must have following two ports connected to the management network:
| + | |
− | | + | |
− | * 1GE IPMI port
| + | |
− | ** IPMI - Intelligent Platform Management Interface.
| + | |
− | ** Required for access to embedded server management with WebUI, CLI, SNMPv3, IPMIv2.0, for firmware (BIOS) and OS updates.
| + | |
− | * 1GE/10GE management port
| + | |
− | ** hostOS management port for general system management.
| + | |
− | | + | |
− | === Server and Port Naming Convention ===
| + | |
− | | + | |
− | Following naming convention is used within this page to specify physical connectivity and wiring across defined CSIT testbeds:
| + | |
− | | + | |
− | <pre>
| + | |
− | - testbedname: testbedN. | + | |
− | - hostname:
| + | |
− | - traffic-generator: tN-tgW.
| + | |
− | - system-under-testX: tN-sutX.
| + | |
− | - portnames:
| + | |
− | - tN-tgW-cY/pZ.
| + | |
− | - tN-sutX-cY/pZ.
| + | |
− | - where:
| + | |
− | - N - testbed number.
| + | |
− | - tgW - server acts as traffic-generator with W index.
| + | |
− | - sutX - server acts as system-under-test with X index.
| + | |
− | - Y - PCIe slot number denoting a NIC card number within the host.
| + | |
− | - Y=2,4,9 - slots connected to NUMA node 0.
| + | |
− | - Y=6,8,10 - slots connected to NUMA node 1.
| + | |
− | - Z - port number on the NIC card.
| + | |
− | </pre>
| + | |
− | | + | |
− | === Server Management - Addressing ===
| + | |
− | | + | |
− | Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a Management port, which are connected to two different VLANs.
| + | |
− | | + | |
− | <pre>
| + | |
− | 1. LOM (IPMI) VLAN:
| + | |
− | - Subnet: 10.30.50.0/24
| + | |
− | - Gateway: 10.30.50.1
| + | |
− | - Broadcast: 10.30.50.255
| + | |
− | - DNS1: 199.204.44.24
| + | |
− | - DNS2: 199.204.47.54
| + | |
− | 2. Management Vlan:
| + | |
− | - Subnet: 10.30.51.0/24
| + | |
− | - Gateway: 10.30.51.1
| + | |
− | - Broadcast: 10.30.51.255
| + | |
− | - DNS1: 199.204.44.24
| + | |
− | - DNS2: 199.204.47.54
| + | |
− | </pre>
| + | |
− | | + | |
− | To access these hosts, an VPN connection is required.
| + | |
− | | + | |
− | === LOM (IPMI) VLAN IP Addresses ===
| + | |
− | | + | |
− | <..>
| + | |
− | | + | |
− | === Management VLAN IP Addresses ===
| + | |
− | | + | |
− | <..>
| + | |
− | | + | |
− | == Testbeds Specification - Target Build ==
| + | |
− | | + | |
− | === Server/Ports Naming, NIC Placement ===
| + | |
− | | + | |
− | ==== 1-Node Xeon ====
| + | |
− | | + | |
− | Each server in 1-node Xeon topology has its NIC cards placed, and NIC cards and ports indexed per following specification:
| + | |
− | | + | |
− | <pre>
| + | |
− | - Server1 [Type-6]:
| + | |
− | - testbedname: testbed11.
| + | |
− | - hostname: s1-t11-sut1.
| + | |
− | - IPMI IP: 10.30.50.47
| + | |
− | - Host IP: 10.30.51.50
| + | |
− | - portnames:
| + | |
− | - s1-t11-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
| + | |
− | - s1-t11-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
| + | |
− | - s1-t11-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
| + | |
− | - s1-t11-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
| + | |
− | - s1-t11-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
| + | |
− | - s1-t11-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
| + | |
− | - s1-t11-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
| + | |
− | - s1-t11-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
| + | |
− | - Server2 [Type-6]:
| + | |
− | - testbedname: testbed12.
| + | |
− | - hostname: s2-t12-sut1.
| + | |
− | - IPMI IP: 10.30.50.48
| + | |
− | - Host IP: 10.30.51.51
| + | |
− | - portnames:
| + | |
− | - s2-t12-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
| + | |
− | - s2-t12-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
| + | |
− | - s2-t12-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
| + | |
− | - s2-t12-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
| + | |
− | - s2-t12-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
| + | |
− | - s2-t12-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
| + | |
− | - s2-t12-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
| + | |
− | - s2-t12-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
| + | |
− | </pre>
| + | |
− | | + | |
− | ==== 2-Node Xeon ====
| + | |
− | | + | |
− | Each server in 2-node Xeon topology has its NIC cards placed, and NIC cards and ports indexed per following specification:
| + | |
− | | + | |
− | <pre>
| + | |
− | - Server3 [Type-1]:
| + | |
− | - testbedname: testbed21.
| + | |
− | - hostname: s3-t21-sut1.
| + | |
− | - IPMI IP: 10.30.50.41
| + | |
− | - Host IP: 10.30.51.44
| + | |
− | - portnames:
| + | |
− | - s3-t21-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
| + | |
− | - s3-t21-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
| + | |
− | - s3-t21-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
| + | |
− | - s3-t21-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
| + | |
− | - s3-t21-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
| + | |
− | - s3-t21-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
| + | |
− | - s3-t21-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
| + | |
− | - s3-t21-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
| + | |
− | - Server4 [Type-2]:
| + | |
− | - testbedname: testbed21.
| + | |
− | - hostname: s4-t21-tg1.
| + | |
− | - IPMI IP: 10.30.50.42
| + | |
− | - Host IP: 10.30.51.45
| + | |
− | - portnames:
| + | |
− | - s4-t21-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
| + | |
− | - s4-t21-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
| + | |
− | - s4-t21-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
| + | |
− | - s4-t21-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
| + | |
− | - s4-t21-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
| + | |
− | - s4-t21-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
| + | |
− | - s4-t21-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
| + | |
− | - s4-t21-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
| + | |
− | - Server5 [Type-1]:
| + | |
− | - testbedname: testbed22.
| + | |
− | - hostname: s5-t22-sut1.
| + | |
− | - IPMI IP: 10.30.50.49
| + | |
− | - Host IP: 10.30.51.52
| + | |
− | - portnames:
| + | |
− | - s5-t22-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
| + | |
− | - s5-t22-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
| + | |
− | - s5-t22-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
| + | |
− | - s5-t22-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
| + | |
− | - s5-t22-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
| + | |
− | - s5-t22-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
| + | |
− | - s5-t22-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
| + | |
− | - s5-t22-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
| + | |
− | - Server6 [Type-2]:
| + | |
− | - testbedname: testbed22.
| + | |
− | - hostname: s6-t22-tg1.
| + | |
− | - IPMI IP: 10.30.50.50
| + | |
− | - Host IP: 10.30.51.53
| + | |
− | - portnames:
| + | |
− | - s6-t22-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
| + | |
− | - s6-t22-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
| + | |
− | - s6-t22-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
| + | |
− | - s6-t22-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
| + | |
− | - s6-t22-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
| + | |
− | - s6-t22-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
| + | |
− | - s6-t22-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
| + | |
− | - s6-t22-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
| + | |
− | - Server7 [Type-1]:
| + | |
− | - testbedname: testbed23.
| + | |
− | - hostname: s7-t23-sut1.
| + | |
− | - IPMI IP: 10.30.50.51
| + | |
− | - Host IP: 10.30.51.54
| + | |
− | - portnames:
| + | |
− | - s7-t23-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
| + | |
− | - s7-t23-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
| + | |
− | - s7-t23-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
| + | |
− | - s7-t23-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
| + | |
− | - s7-t23-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
| + | |
− | - s7-t23-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
| + | |
− | - s7-t23-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
| + | |
− | - s7-t23-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
| + | |
− | - Server8 [Type-2]:
| + | |
− | - testbedname: testbed23.
| + | |
− | - hostname: s8-t23-tg1.
| + | |
− | - IPMI IP: 10.30.50.52
| + | |
− | - Host IP: 10.30.51.55
| + | |
− | - portnames:
| + | |
− | - s8-t23-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
| + | |
− | - s8-t23-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
| + | |
− | - s8-t23-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
| + | |
− | - s8-t23-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
| + | |
− | - s8-t23-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
| + | |
− | - s8-t23-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
| + | |
− | - s8-t23-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
| + | |
− | - s8-t23-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
| + | |
− | - Server9 [Type-1]:
| + | |
− | - testbedname: testbed24.
| + | |
− | - hostname: s9-t24-sut1.
| + | |
− | - IPMI IP: 10.30.50.53
| + | |
− | - Host IP: 10.30.51.56
| + | |
− | - portnames:
| + | |
− | - s9-t24-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
| + | |
− | - s9-t24-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
| + | |
− | - s9-t24-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
| + | |
− | - s9-t24-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
| + | |
− | - s9-t24-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
| + | |
− | - s9-t24-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
| + | |
− | - s9-t24-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
| + | |
− | - s9-t24-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
| + | |
− | - Server10 [Type-2]:
| + | |
− | - testbedname: testbed21.
| + | |
− | - hostname: s10-t24-tg1.
| + | |
− | - IPMI IP: 10.30.50.54
| + | |
− | - Host IP: 10.30.51.57
| + | |
− | - portnames:
| + | |
− | - s10-t24-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
| + | |
− | - s10-t24-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
| + | |
− | - s10-t24-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
| + | |
− | - s10-t24-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
| + | |
− | - s10-t24-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
| + | |
− | - s10-t24-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
| + | |
− | - s10-t24-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
| + | |
− | - s10-t24-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
| + | |
− | </pre>
| + | |
− | | + | |
− | ==== 3-Node Xeon ====
| + | |
− | | + | |
− | Each server in 3-node Xeon topology has its NIC cards placed, and NIC cards and ports indexed per following specification:
| + | |
− | | + | |
− | <pre>
| + | |
− | - Server11 [Type-1]:
| + | |
− | - testbedname: testbed31.
| + | |
− | - hostname: s11-t31-sut1.
| + | |
− | - IPMI IP: 10.30.50.43
| + | |
− | - Host IP: 10.30.51.46
| + | |
− | - portnames:
| + | |
− | - s11-t31-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
| + | |
− | - s11-t31-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
| + | |
− | - s11-t31-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
| + | |
− | - s11-t31-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
| + | |
− | - s11-t31-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
| + | |
− | - s11-t31-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
| + | |
− | - s11-t31-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
| + | |
− | - s11-t31-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
| + | |
− | - Server12 [Type-1]:
| + | |
− | - testbedname: testbed31.
| + | |
− | - hostname: s12-t31-sut2.
| + | |
− | - IPMI IP: 10.30.50.44
| + | |
− | - Host IP: 10.30.51.47
| + | |
− | - portnames:
| + | |
− | - s12-t31-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
| + | |
− | - s12-t31-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
| + | |
− | - s12-t31-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
| + | |
− | - s12-t31-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
| + | |
− | - s12-t31-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
| + | |
− | - s12-t31-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
| + | |
− | - s12-t31-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
| + | |
− | - s12-t31-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
| + | |
− | - Server13 [Type-2]:
| + | |
− | - testbedname: testbed31.
| + | |
− | - hostname: s13-t31-tg1.
| + | |
− | - IPMI IP: 10.30.50.45
| + | |
− | - Host IP: 10.30.51.48
| + | |
− | - portnames:
| + | |
− | - s13-t31-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
| + | |
− | - s13-t31-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
| + | |
− | - s13-t31-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
| + | |
− | - s13-t31-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
| + | |
− | - s13-t31-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
| + | |
− | - s13-t31-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
| + | |
− | - s13-t31-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
| + | |
− | - s13-t31-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
| + | |
− | - Server14 [Type-1]:
| + | |
− | - testbedname: testbed32.
| + | |
− | - hostname: s14-t32-sut1.
| + | |
− | - IPMI IP: 10.30.50.55
| + | |
− | - Host IP: 10.30.51.58
| + | |
− | - portnames:
| + | |
− | - s14-t32-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
| + | |
− | - s14-t32-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
| + | |
− | - s14-t32-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
| + | |
− | - s14-t32-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
| + | |
− | - s14-t32-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
| + | |
− | - s14-t32-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
| + | |
− | - s14-t32-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
| + | |
− | - s14-t32-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
| + | |
− | - Server15 [Type-1]:
| + | |
− | - testbedname: testbed32.
| + | |
− | - hostname: s15-t32-sut2.
| + | |
− | - IPMI IP: 10.30.50.56
| + | |
− | - Host IP: 10.30.51.59
| + | |
− | - portnames:
| + | |
− | - s15-t32-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
| + | |
− | - s15-t32-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
| + | |
− | - s15-t32-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
| + | |
− | - s15-t32-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
| + | |
− | - s15-t32-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
| + | |
− | - s15-t32-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
| + | |
− | - s15-t32-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
| + | |
− | - s15-t32-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
| + | |
− | - Server16 [Type-2]:
| + | |
− | - testbedname: testbed32.
| + | |
− | - hostname: s16-t32-tg1.
| + | |
− | - IPMI IP: 10.30.50.57
| + | |
− | - Host IP: 10.30.51.60
| + | |
− | - portnames:
| + | |
− | - s16-t32-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
| + | |
− | - s16-t32-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
| + | |
− | - s16-t32-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
| + | |
− | - s16-t32-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
| + | |
− | - s16-t32-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
| + | |
− | - s16-t32-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
| + | |
− | - s16-t32-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
| + | |
− | - s16-t32-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
| + | |
− | </pre>
| + | |
− | | + | |
− | ==== 3-Node Arm ====
| + | |
− | | + | |
− | Note: Server19 (TG) is shared between testbed33 & testbed34
| + | |
− | | + | |
− | <pre>
| + | |
− | - Server17 [Type-3]:
| + | |
− | - testbedname: testbed33.
| + | |
− | - hostname: s17-t33-sut1.
| + | |
− | - IPMI IP: 10.30.50.36
| + | |
− | - Host IP: 10.30.51.36
| + | |
− | - portnames:
| + | |
− | - s17-t33-sut1-ca/p1 - 10GE-port1 82599-2p10GE.
| + | |
− | - s17-t33-sut1-ca/p2 - 10GE-port2 82599-2p10GE.
| + | |
− | - s17-t33-sut1-c2/p1 - 25GE-port1 cx4-2p25GE.
| + | |
− | - s17-t33-sut1-c2/p2 - 25GE-port2 cx4-2p25GE.
| + | |
− | - Server18 [Type-3]:
| + | |
− | - testbedname: testbed33.
| + | |
− | - hostname: s18-t33-sut2.
| + | |
− | - IPMI IP: 10.30.50.37
| + | |
− | - Host IP: 10.30.51.37
| + | |
− | - portnames:
| + | |
− | - s18-t33-sut2-ca/p1 - 10GE-port1 82599-2p10GE.
| + | |
− | - s18-t33-sut2-ca/p2 - 10GE-port2 82599-2p10GE.
| + | |
− | - s18-t33-sut2-c2/p1 - 25GE-port1 cx4-2p25GE.
| + | |
− | - s18-t33-sut2-c2/p2 - 25GE-port2 cx4-2p25GE.
| + | |
− | - Server19 [Type-2]:
| + | |
− | - testbedname: testbed33.
| + | |
− | - hostname: s19-t33t34-tg1.
| + | |
− | - IPMI IP: 10.30.50.46
| + | |
− | - Host IP: 10.30.51.49
| + | |
− | - portnames:
| + | |
− | - s19-t33t34-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
| + | |
− | - s19-t33t34-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
| + | |
− | - s19-t33t34-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
| + | |
− | - s19-t33t34-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
| + | |
− | - s19-t33t34-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
| + | |
− | - s19-t33t34-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
| + | |
− | - Server20 [Type-4]:
| + | |
− | - testbedname: testbed34.
| + | |
− | - hostname: s20-t34-sut1.
| + | |
− | - IPMI IP: N/A
| + | |
− | - Host IP: 10.30.51.41
| + | |
− | - portnames:
| + | |
− | - s20-t34-sut1-ca/p1 - 10GE-port1 Marvell.
| + | |
− | - s20-t34-sut1-ca/p2 - 10GE-port2 Marvell.
| + | |
− | - Server21 [Type-4]:
| + | |
− | - testbedname: testbed34.
| + | |
− | - hostname: s21-t34-sut2.
| + | |
− | - IPMI IP: N/A
| + | |
− | - Host IP: 10.30.51.42
| + | |
− | - portnames:
| + | |
− | - s21-t34-sut2-ca/p1 - 10GE-port1 Marvell.
| + | |
− | - s21-t34-sut2-ca/p2 - 10GE-port2 Marvell.
| + | |
− | </pre>
| + | |
− | | + | |
− | ==== TCP/IP and L47 ====
| + | |
− | | + | |
− | Each server (appliance) in 2-node TCP/IP topology has its NIC cards placed, and NIC cards and ports indexed per following specification:
| + | |
− | | + | |
− | <pre>
| + | |
− | - Server25 [Type-8]:
| + | |
− | - testbedname: testbed25.
| + | |
− | - hostname: s25-t25-sut1.
| + | |
− | - IPMI IP: 10.30.50.58
| + | |
− | - Host IP: 10.30.51.61
| + | |
− | - portnames:
| + | |
− | - s25-t25-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
| + | |
− | - s25-t25-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
| + | |
− | - s25-t25-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
| + | |
− | - s25-t25-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
| + | |
− | - Server26 [Type-7]:
| + | |
− | - testbedname: testbed25.
| + | |
− | - hostname: s26-t25-tg1.
| + | |
− | - IPMI IP: 10.30.50.59
| + | |
− | - Host IP: 10.30.51.62
| + | |
− | - portnames:
| + | |
− | - s26-t25-tg1-p1 - 10GE-port1.
| + | |
− | - s26-t25-tg1-p2 - 10GE-port2.
| + | |
− | - s26-t25-tg1-p3 - 10GE-port3.
| + | |
− | - s26-t25-tg1-p4 - 10GE-port4.
| + | |
− | </pre>
| + | |
− | | + | |
− | ==== 3-Node Atom ====
| + | |
− | | + | |
− | Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
| + | |
− | | + | |
− | <pre>
| + | |
− | - Server22 [Type-5]:
| + | |
− | - testbedname: testbed35.
| + | |
− | - hostname: s22-t35-sut1 (vex-yul-rot-netgate-1).
| + | |
− | - IPMI IP: 10.30.51.29 - screen -r /dev/ttyUSB0
| + | |
− | - Host IP: 10.30.51.9
| + | |
− | - portnames:
| + | |
− | - s22-t35-sut1-p1 - 10GE-port1 ix0 82599.
| + | |
− | - s22-t35-sut1-p2 - 10GE-port2 ix1 82599.
| + | |
− | - 1GB ports (tbd)
| + | |
− | - Server23 [Type-5]:
| + | |
− | - testbedname: testbed35.
| + | |
− | - hostname: s23-t35-sut2 (vex-yul-rot-netgate-2).
| + | |
− | - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB1
| + | |
− | - Host IP: 10.30.51.10
| + | |
− | - portnames:
| + | |
− | - s23-t35-sut1-p1 - 10GE-port1 ix0 82599.
| + | |
− | - s23-t35-sut1-p2 - 10GE-port2 ix1 82599.
| + | |
− | - 1GB ports (tbd)
| + | |
− | - Server24 [Type-5]:
| + | |
− | - testbedname: testbed35.
| + | |
− | - hostname: s24-t35-sut3 (vex-yul-rot-netgate-3).
| + | |
− | - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB2
| + | |
− | - Host IP: 10.30.51.11
| + | |
− | - portnames:
| + | |
− | - s24-t35-sut1-p1 - 10GE-port1 ix0 82599.
| + | |
− | - s24-t35-sut1-p2 - 10GE-port2 ix1 82599.
| + | |
− | - 1GB ports (tbd)
| + | |
− | </pre>
| + | |
− | | + | |
− | === Physical Connectivity within Testbeds ===
| + | |
− | | + | |
− | ==== 1-Node Xeon ====
| + | |
− | | + | |
− | Two 1-Node testbeds are constructed by connecting 2 Xeon servers using below specification:
| + | |
− | | + | |
− | <pre>
| + | |
− | - testbed11:
| + | |
− | - ring1 10GE-ports x710-4p10GE:
| + | |
− | - s1-t11-sut1-c2/p1 to s1-t11-sut1-c4/p1.
| + | |
− | - ring2 10GE-ports x710-4p10GE:
| + | |
− | - s1-t11-sut1-c2/p2 to s1-t11-sut1-c4/p2.
| + | |
− | - ring3 10GE-ports x710-4p10GE:
| + | |
− | - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
| + | |
− | - ring4 10GE-ports x710-4p10GE:
| + | |
− | - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
| + | |
− | - testbed12:
| + | |
− | - ring1 10GE-ports x710-4p10GE:
| + | |
− | - s2-t12-sut1-c2/p1 to s2-t12-sut1-c4/p1.
| + | |
− | - ring2 10GE-ports x710-4p10GE:
| + | |
− | - s2-t12-sut1-c2/p2 to s2-t12-sut1-c4/p2.
| + | |
− | - ring3 10GE-ports x710-4p10GE:
| + | |
− | - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
| + | |
− | - ring4 10GE-ports x710-4p10GE:
| + | |
− | - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
| + | |
− | </pre>
| + | |
− | | + | |
− | ==== 2-Node Xeon ====
| + | |
− | | + | |
− | Four 2-Node testbeds are constructed by connecting 8 Xeon servers using below specification:
| + | |
− | | + | |
− | <pre>
| + | |
− | - testbed21:
| + | |
− | - ring1 10GE-ports x710-4p10GE on SUT:
| + | |
− | - t21-tg1-c2/p1 to t21-sut1-c2/p1.
| + | |
− | - t21-sut1-c2/p2 to t21-tg1-c2/p2.
| + | |
− | - ring2 10GE-ports x710-4p10GE on SUT:
| + | |
− | - t21-tg1-c2/p3 to t21-sut1-c2/p3.
| + | |
− | - t21-sut1-c2/p4 to t21-tg1-c2/p4.
| + | |
− | - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
| + | |
− | - t21-tg1-c4/p1 to t21-sut1-c4/p1.
| + | |
− | - t21-sut1-c4/p2 to t21-tg1-c4/p2.
| + | |
− | - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
| + | |
− | - t21-tg1-c9/p1 to t21-sut1-c9/p1.
| + | |
− | - t21-sut1-c9/p2 to t21-tg1-c9/p2.
| + | |
− | - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
| + | |
− | - t21-tg1-c10/p1 to t21-tg1-c10/p2.
| + | |
− | - t21-tg1-c10/p3 to t21-tg1-c10/p4.
| + | |
− | - testbed22:
| + | |
− | - ring1 10GE-ports x710-4p10GE on SUT:
| + | |
− | - t22-tg1-c2/p1 to t22-sut1-c2/p1.
| + | |
− | - t22-sut1-c2/p2 to t22-tg1-c2/p2.
| + | |
− | - ring2 10GE-ports x710-4p10GE on SUT:
| + | |
− | - t22-tg1-c2/p3 to t22-sut1-c2/p3.
| + | |
− | - t22-sut1-c2/p4 to t22-tg1-c2/p4.
| + | |
− | - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
| + | |
− | - t22-tg1-c4/p1 to t22-sut1-c4/p1.
| + | |
− | - t22-sut1-c4/p2 to t22-tg1-c4/p2.
| + | |
− | - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
| + | |
− | - t22-tg1-c9/p1 to t22-sut1-c9/p1.
| + | |
− | - t22-sut1-c9/p2 to t22-tg1-c9/p2.
| + | |
− | - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
| + | |
− | - t22-tg1-c10/p1 to t22-tg1-c10/p2.
| + | |
− | - t22-tg1-c10/p3 to t22-tg1-c10/p4.
| + | |
− | - testbed23:
| + | |
− | - ring1 10GE-ports x710-4p10GE on SUT:
| + | |
− | - t23-tg1-c2/p1 to t23-sut1-c2/p1.
| + | |
− | - t23-sut1-c2/p2 to t23-tg1-c2/p2.
| + | |
− | - ring2 10GE-ports x710-4p10GE on SUT:
| + | |
− | - t23-tg1-c2/p3 to t23-sut1-c2/p3.
| + | |
− | - t23-sut1-c2/p4 to t23-tg1-c2/p4.
| + | |
− | - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
| + | |
− | - t23-tg1-c4/p1 to t23-sut1-c4/p1.
| + | |
− | - t23-sut1-c4/p2 to t23-tg1-c4/p2.
| + | |
− | - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
| + | |
− | - t23-tg1-c9/p1 to t23-sut1-c9/p1.
| + | |
− | - t23-sut1-c9/p2 to t23-tg1-c9/p2.
| + | |
− | - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
| + | |
− | - t23-tg1-c10/p1 to t23-tg1-c10/p2.
| + | |
− | - t23-tg1-c10/p3 to t23-tg1-c10/p4.
| + | |
− | - testbed24:
| + | |
− | - ring1 10GE-ports x710-4p10GE on SUT:
| + | |
− | - t24-tg1-c2/p1 to t24-sut1-c2/p1.
| + | |
− | - t24-sut1-c2/p2 to t24-tg1-c2/p2.
| + | |
− | - ring2 10GE-ports x710-4p10GE on SUT:
| + | |
− | - t24-tg1-c2/p3 to t24-sut1-c2/p3.
| + | |
− | - t24-sut1-c2/p4 to t24-tg1-c2/p4.
| + | |
− | - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
| + | |
− | - t24-tg1-c4/p1 to t24-sut1-c4/p1.
| + | |
− | - t24-sut1-c4/p2 to t24-tg1-c4/p2.
| + | |
− | - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
| + | |
− | - t24-tg1-c9/p1 to t24-sut1-c9/p1.
| + | |
− | - t24-sut1-c9/p2 to t24-tg1-c9/p2.
| + | |
− | - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
| + | |
− | - t24-tg1-c10/p1 to t24-tg1-c10/p2.
| + | |
− | - t24-tg1-c10/p3 to t24-tg1-c10/p4.
| + | |
− | </pre>
| + | |
− | | + | |
− | ==== 3-Node Xeon ====
| + | |
− | | + | |
− | Two 3-Node testbeds are constructed by connecting 6 Xeon servers using below specification:
| + | |
− | | + | |
− | <pre>
| + | |
− | - testbed31:
| + | |
− | - ring1 10GE-ports x710-4p10GE on SUTs:
| + | |
− | - t31-tg1-c2/p1 to t31-sut1-c2/p1.
| + | |
− | - t31-sut1-c2/p2 to t31-sut2-c2/p2.
| + | |
− | - t31-sut2-c2/p1 to t31-tg1-c2/p2.
| + | |
− | - ring2 10GE-ports x710-4p10GE on SUT:
| + | |
− | - t31-tg1-c2/p3 to t31-sut1-c2/p3.
| + | |
− | - t31-sut1-c2/p4 to t31-sut2-c2/p4.
| + | |
− | - t31-sut2-c2/p3 to t31-tg1-c2/p4.
| + | |
− | - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
| + | |
− | - t31-tg1-c4/p1 to t31-sut1-c4/p1.
| + | |
− | - t31-sut1-c4/p2 to t31-sut2-c4/p2.
| + | |
− | - t31-sut2-c4/p1 to t31-tg1-c4/p2.
| + | |
− | - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
| + | |
− | - t31-tg1-c9/p1 to t31-sut1-c9/p1.
| + | |
− | - t31-sut1-c9/p2 to t31-sut2-c9/p2.
| + | |
− | - t31-sut2-c9/p1 to t31-tg1-c9/p2.
| + | |
− | - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
| + | |
− | - t31-tg1-c10/p1 to t31-tg1-c10/p2.
| + | |
− | - t31-tg1-c10/p3 to t31-tg1-c10/p4.
| + | |
− | - testbed32:
| + | |
− | - ring1 10GE-ports x710-4p10GE on SUTs:
| + | |
− | - t32-tg1-c2/p1 to t32-sut1-c2/p1.
| + | |
− | - t32-sut1-c2/p2 to t32-sut2-c2/p2.
| + | |
− | - t32-sut2-c2/p1 to t32-tg1-c2/p2.
| + | |
− | - ring2 10GE-ports x710-4p10GE on SUT:
| + | |
− | - t32-tg1-c2/p3 to t32-sut1-c2/p3.
| + | |
− | - t32-sut1-c2/p4 to t32-sut2-c2/p4.
| + | |
− | - t32-sut2-c2/p3 to t32-tg1-c2/p4.
| + | |
− | - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
| + | |
− | - t32-tg1-c4/p1 to t32-sut1-c4/p1.
| + | |
− | - t32-sut1-c4/p2 to t32-sut2-c4/p2.
| + | |
− | - t32-sut2-c4/p1 to t32-tg1-c4/p2.
| + | |
− | - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
| + | |
− | - t32-tg1-c9/p1 to t32-sut1-c9/p1.
| + | |
− | - t32-sut1-c9/p2 to t32-sut2-c9/p2.
| + | |
− | - t32-sut2-c9/p1 to t32-tg1-c9/p2.
| + | |
− | - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
| + | |
− | - t32-tg1-c10/p1 to t32-tg1-c10/p2.
| + | |
− | - t32-tg1-c10/p3 to t32-tg1-c10/p4.
| + | |
− | </pre>
| + | |
− | | + | |
− | ==== 3-Node Arm ====
| + | |
− | | + | |
− | One 3-Node testbed is constructed by connecting 3 Arm servers using below specification:
| + | |
− | | + | |
− | <pre>
| + | |
− | - testbed33:
| + | |
− | - ring1 10GE-ports 82599-2p10GE on SUTs:
| + | |
− | - t33t34-tg1-c2/p1 - t33-sut1-ca/p1.
| + | |
− | - t33-sut1-ca/p2 - t33-sut2-ca/p1.
| + | |
− | - t33-sut2-ca/p2 - t33t34-tg1-c2/p2.
| + | |
− | - ring2 25GE-ports cx4-2p25GE on SUTs:
| + | |
− | - t33t34-tg1-c4/p1 - t33-sut1-c2/p1.
| + | |
− | - t33-sut1-c2/p2 - t33-sut2-c2/p1.
| + | |
− | - t33-sut2-c2/p2 - t33t34-tg1-c4/p2.
| + | |
− | - testbed34:
| + | |
− | - ring1 10GE-ports Marvell on SUTs:
| + | |
− | - t33t34-tg1-c2/p3 - t34-sut1-ca/p1.
| + | |
− | - t34-sut1-ca/p2 - t34-sut2-ca/p1.
| + | |
− | - t34-sut2-ca/p2 - t33t34-tg1-c2/p4.
| + | |
− | </pre>
| + | |
− | | + | |
− | ==== TCP/IP and L47 ====
| + | |
− | | + | |
− | One 2-Node TCP/IP testbed is constructed by connecting Ixia PSOne and 1 Xeon server using below specification:
| + | |
− | | + | |
− | <pre>
| + | |
− | - testbed25:
| + | |
− | - link1 10GE-port x710-4p10GE on SUT:
| + | |
− | - t25-tg1-p1 to t25-sut1-c2/p1.
| + | |
− | - link2 10GE-port x710-4p10GE on SUT:
| + | |
− | - t25-tg1-p2 to t25-sut1-c2/p2.
| + | |
− | - link3 10GE-port x710-4p10GE on SUT:
| + | |
− | - t25-tg1-p3 to t25-sut1-c2/p3.
| + | |
− | - link4 10GE-port x710-4p10GE on SUT:
| + | |
− | - t25-tg1-p4 to t25-sut1-c2/p4.
| + | |
− | </pre>
| + | |
− | | + | |
− | ==== 3-Node Atom ====
| + | |
− | | + | |
− | <..>
| + | |
− | | + | |
− | === Host OS and configuration ===
| + | |
− | | + | |
− | <..>
| + | |
− | | + | |
− | ==== SUTs ====
| + | |
− | | + | |
− | <..>
| + | |
− | | + | |
− | ==== TG ====
| + | |
− | | + | |
− | <..>
| + | |
− | | + | |
− | == Server Specification ==
| + | |
− | | + | |
− | The new FD.io CSIT-CPL lab (is expected to contain|contains) following hardware server configurations:
| + | |
− | | + | |
− | <pre>
| + | |
− | 1. Type-1: Purpose - (Intel Xeon Processor) SUT for SW Data Plane Workload i.e. VPP, testpmd.
| + | |
− | - Quantity: TBD based on testbed allocation.
| + | |
− | - Physical connectivity:
| + | |
− | - IPMI and host management ports.
| + | |
− | - NIC ports connected into 2-node and 3-node topologies.
| + | |
− | - Main HW configuration:
| + | |
− | - Chassis: SuperMicro SYS-7049GP-TRT.
| + | |
− | - Motherboard: SuperMicro X11DPG-QT.
| + | |
− | - Processors: 2* Intel Platinum 8180 2.3 GHz.
| + | |
− | - RAM Memory: 16* 16GB DDR4-2666MHz.
| + | |
− | - Disks: 2* 1.6TB 6G SATA SSD.
| + | |
− | - NICs configuration:
| + | |
− | - Numa0: (x16, x16, x16 PCIe3.0 lanes)
| + | |
− | - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
| + | |
− | - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
| + | |
− | - PCIe Slot9 5e:00.xx: FUTURE ConnectX5-2p100GE Mellanox.
| + | |
− | - Numa1: (x16, x16, x16 PCIe3.0 lanes)
| + | |
− | - PCIe Slot6 86:00.xx: empty.
| + | |
− | - PCIe Slot8 af:00.xx: empty.
| + | |
− | - PCIe Slot10 d8:00.xx: empty.
| + | |
− | 2. Type-2: Purpose - (Intel Xeon Processor) TG for T-Rex.
| + | |
− | - Quantity: TBD based on testbed allocation.
| + | |
− | - Physical connectivity:
| + | |
− | - IPMI and host management ports.
| + | |
− | - NIC ports connected into 2-node and 3-node topologies.
| + | |
− | - Main HW configuration:
| + | |
− | - Chassis: SuperMicro SYS-7049GP-TRT.
| + | |
− | - Motherboard: SuperMicro X11DPG-QT.
| + | |
− | - Processors: 2* Intel Platinum 8180 2.3 GHz.
| + | |
− | - RAM Memory: 16* 16GB DDR4-2666MHz.
| + | |
− | - Disks: 2* 1.6TB 6G SATA SSD.
| + | |
− | - NICs configuration:
| + | |
− | - Numa0: (x16, x16, x16 PCIe3.0 lanes)
| + | |
− | - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
| + | |
− | - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
| + | |
− | - PCIe Slot9 5e:00.xx: FUTURE ConnectX5-2p100GE Mellanox.
| + | |
− | - Numa1: (x16, x16, x16 PCIe3.0 lanes)
| + | |
− | - PCIe Slot6 86:00.xx: empty.
| + | |
− | - PCIe Slot8 af:00.xx: empty.
| + | |
− | - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
| + | |
− | 3. Type-3: Purpose - (Arm hip07-d05 Processor) SUT for SW Data Plane Workload i.e. VPP, testpmd.
| + | |
− | - Quantity: 2
| + | |
− | - Physical connectivity:
| + | |
− | - IPMI(?) and host management ports.
| + | |
− | - NIC ports connected into 3-node topology.
| + | |
− | - Main HW configuration:
| + | |
− | - Chassis: Huawei TaiShan 2280.
| + | |
− | - Processors: 1* hip07-d05 ~ 64* Arm Cortex-A72
| + | |
− | - RAM Memory: 8* 16GB DDR4-2400MT/s
| + | |
− | - Disks: 1* 4TB SATA HDD
| + | |
− | - NICs configuration:
| + | |
− | - PCIe Slot2 e9:00.xx: connectx4-2p25GE Mellanox.
| + | |
− | - PCIe Slota 11:00.xx: 82599-2p10GE Intel.
| + | |
− | 4. Type-4: Purpose - (Arm Armada 8040 Processor) SUT for SW Data Plane Workload i.e. VPP, testpmd.
| + | |
− | - Quantity: 3
| + | |
− | - Physical connectivity:
| + | |
− | - Host management ports.
| + | |
− | - NIC ports connected into 2-node and 3-node topologies.
| + | |
− | - Main HW configuration:
| + | |
− | - Chassis: MACCHIATObin.
| + | |
− | - Processors: 1* Armada 8040 ~ 4* Arm Cortex-A72
| + | |
− | - RAM Memory: 1* 16GB DDR4
| + | |
− | - Disks: 1* 128GB(?) SATA SDD
| + | |
− | - NICs configuration:
| + | |
− | - pp2-2p10GE Marvell (on-chip Ethernet ports ; marvell plugin in VPP)
| + | |
− | 5. Type-5: Purpose - (Intel Atom Processor) SUT for SW Data Plane Workload i.e. VPP, testpmd.
| + | |
− | - Quantity: TBD based on testbed allocation.
| + | |
− | - Physical connectivity:
| + | |
− | - Management: serial Port (usb) for console
| + | |
− | - NIC ports connected into 2-node.
| + | |
− | - Main HW configuration:
| + | |
− | - Chassis: Netgate XG-2758-1u
| + | |
− | - Processors: 1* Rangely (Atom) C2758 2.4 GHz
| + | |
− | - RAM Memory: 16GB ECC
| + | |
− | - Disks: 150 GB
| + | |
− | - NICs configuration:
| + | |
− | - 2x 10Gb Intel 82599ES
| + | |
− | - 4x 1GB Intel I354
| + | |
− | 6. Type-6: Purpose - (Intel Xeon Processor) SUT for VPP_Device functional tests.
| + | |
− | - Quantity: 1.
| + | |
− | - Physical connectivity:
| + | |
− | - IPMI and host management ports.
| + | |
− | - NIC ports connected into 2-node and 3-node topologies.
| + | |
− | - Main HW configuration:
| + | |
− | - Chassis: SuperMicro SYS-7049GP-TRT.
| + | |
− | - Motherboard: SuperMicro X11DPG-QT.
| + | |
− | - Processors: 2* Intel Platinum 8180 2.3 GHz.
| + | |
− | - RAM Memory: 16* 16GB DDR4-2666MHz.
| + | |
− | - Disks: 2* 1.6TB 6G SATA SSD.
| + | |
− | - NICs configuration:
| + | |
− | - Numa0: (x16, x16, x16 PCIe3.0 lanes)
| + | |
− | - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
| + | |
− | - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
| + | |
− | - PCIe Slot9 5e:00.xx: empty.
| + | |
− | - Numa1: (x16, x16, x16 PCIe3.0 lanes)
| + | |
− | - PCIe Slot6 86:00.xx: empty.
| + | |
− | - PCIe Slot8 af:00.xx: empty.
| + | |
− | - PCIe Slot10 d8:00.xx: empty.
| + | |
− | 7. Type-7: Purpose - Ixia PerfectStorm One Appliance TG for TCP/IP performance tests.
| + | |
− | - Quantity: 1.
| + | |
− | - Physical connectivity:
| + | |
− | - Host management interface: 10/100/1000-BaseT.
| + | |
− | - 8-port 10GE SFP+ integrated NIC.
| + | |
− | - Main HW configuration:
| + | |
− | - Chassis: PS10GE4NG.
| + | |
− | - Motherboard: SuperMicro X11DPG-QT.
| + | |
− | - Processors: Quad-Core, Intel Processor.
| + | |
− | - HW accelerators: FPGA offload.
| + | |
− | - RAM Memory: 64GB.
| + | |
− | - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
| + | |
− | - Physical Interfaces: 4 * 10GE SFP+.
| + | |
− | - Operating System: Native IxOS.
| + | |
− | - Interface configuration:
| + | |
− | - Port-1: 10GE SFP+.
| + | |
− | - Port-2: 10GE SFP+.
| + | |
− | - Port-3: 10GE SFP+.
| + | |
− | - Port-4: 10GE SFP+.
| + | |
− | 8. Type-8: Purpose - (Intel Xeon Processor) SUT for TCP/IP host stack tests.
| + | |
− | - Quantity: 1.
| + | |
− | - Physical connectivity:
| + | |
− | - IPMI and host management ports.
| + | |
− | - NIC ports.
| + | |
− | - Main HW configuration:
| + | |
− | - Chassis: SuperMicro SYS-7049GP-TRT.
| + | |
− | - Motherboard: SuperMicro X11DPG-QT.
| + | |
− | - Processors: 2* Intel Platinum 8180 2.3 GHz.
| + | |
− | - RAM Memory: 16* 16GB DDR4-2666MHz.
| + | |
− | - Disks: 2* 1.6TB 6G SATA SSD.
| + | |
− | - NICs configuration:
| + | |
− | - Numa0: (x16, x16, x16 PCIe3.0 lanes)
| + | |
− | - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
| + | |
− | - PCIe Slot4 3b:00.xx: empty.
| + | |
− | - PCIe Slot9 5e:00.xx: empty.
| + | |
− | - Numa1: (x16, x16, x16 PCIe3.0 lanes)
| + | |
− | - PCIe Slot6 86:00.xx: empty.
| + | |
− | - PCIe Slot8 af:00.xx: empty.
| + | |
− | - PCIe Slot10 d8:00.xx: empty.
| + | |
− | </pre>
| + | |
− | | + | |
− | == Initial Build (Deprecated) ==
| + | |
− | | + | |
− | === Physical Connectivity within Testbeds ===
| + | |
− | | + | |
− | ==== 2-Node Xeon ====
| + | |
− | | + | |
− | One 2-Node testbeds are constructed by connecting 8 Xeon servers using below specification:
| + | |
− | | + | |
− | 1. testbed21:
| + | |
− | - ring3 40GE-ports xl710-2p40GE on SUT
| + | |
− | - t21-tg1-c4/p1 to t21-sut1-c4/p1.
| + | |
− | - t21-sut1-c4/p2 to t21-tg1-c4/p2.
| + | |
− | | + | |
− | ==== 3-Node Xeon ====
| + | |
− | | + | |
− | 1. testbed31:
| + | |
− | - ring1 10GE-ports x710-2p10GE on SUTs:
| + | |
− | - t31-tg1-c2/p1 to t31-sut1-c2/p1.
| + | |
− | - t31-sut1-c2/p2 to t31-sut2-c2/p2.
| + | |
− | - t31-sut2-c2/p1 to t31-tg1-c2/p2.
| + | |
− | - ring2 10GE-ports x710-2p10GE on SUT:
| + | |
− | - t31-tg1-c4/p1 to t31-sut1-c4/p1.
| + | |
− | - t31-sut1-c4/p2 to t31-sut2-c4/p2.
| + | |
− | - t31-sut2-c4/p1 to t31-tg1-c4/p2.
| + | |
− | | + | |
− | ==== 2-Node Atom ====
| + | |
− | | + | |
− | 1. testbed35:
| + | |
− | - (tbd)
| + | |
− | | + | |
− | ==== 3-Node Atom ====
| + | |
− | | + | |
− | 1. testbed35:
| + | |
− | - (tbd)
| + | |