== FD.IO CSIT testbed - Server HW Configuration (Skylake/ARM) ==
+
Content has been moved to [[CSIT/Testbeds:_Xeon_Skx,_Arm,_Atom. | FD.io CSIT testbeds - Xeon Skylake, Arm, Atom]].
 
+
This is a (proposed) low-level design for the extensions of FD.io CSIT lab to accommodate the new Intel Xeon Skylake, Arm AArch64 and Atom devices. The current version is available on [https://wiki.fd.io/view/CSIT/fdio_csit_lab_ext_lld_draft CSIT wiki].
+
 
+
== Testbeds Overview ==
+
 
+
=== Testbeds Type Breakdown ===
+
 
+
<pre>
+
#.  CSIT_tb.          Purpose.    SUT.  TG.  #tb.  #SUTs.  #TGs. #skx_node.
+
1.  1-node Xeon.      func.      skx.  n/a.  2.    2.      0.    2.
+
2.  2-node Xeon.      perf.      skx.  skx.  4.    4.      4.    8.
+
3.  3-node Xeon.      perf.      skx.  skx.  2.    4.      2.    6.
+
4.  tcp-l47.          tcp-stack.  skx.  ps1.  1.    1.      1.    1.
+
5.  atom-netgate.      perf+func.  net.  skx.  1.    3.      1.    1.
+
6.  aarch64-d05        perf+func.  arm.  skx.  2.    2.      1.    1.
+
7.  aarch64-mcbin      perf        arm.  skx.  1.    2.      1.    1.
+
                                                Total skx_node:   20.
+
</pre>
+
 
+
=== 1-Node Xeon Testbeds ===
+
 
+
One 1-node Xeon testbed for VPP_Device tests is built using one SUT (Type-6 server), with NIC ports connected back-to-back.
+
 
+
=== 2-Node Xeon Testbeds ===
+
 
+
Four 2-node Xeon testbeds (are expected to be built|are built), with each testbed using one SUTs (Type-1 server) and one TG (Type-2 server) connected back-to-back. NIC cards placement into slots and NIC ports connectivity is following the testbed specification included in next sections.
+
 
+
=== 3-Node Xeon Testbeds ===
+
 
+
Two 3-node Xeon testbeds (are expected to be built|are built), with each testbed using two SUTs (Type-1 server) and one TG (Type-2 server) connected in full-mesh triangle. NIC cards placement into slots and NIC ports connectivity is following the testbed specification included in next sections.
+
 
+
=== Arm Testbeds ===
+
 
+
One 3-node Huawei testbeds (are expected to be built|are built), with each testbed using two SUTs (Type-3 server) and one TG (Type-2 server) connected in full-mesh triangle.
+
 
+
One 3-node Marvell testbeds (are expected to be built|are built), with each testbed using two SUTs (Type-4 server) and one TG (Type-2 server) connected in full-mesh triangle.
+
 
+
=== TCP/IP and L47 Testbeds ===
+
 
+
One 2-node Ixia PS One and Xeon server testbed, for TCP/IP host stack tests.
+
 
+
=== Atom Testbeds ===
+
 
+
One 3-node Atom (Netgate based) testbed is built consisting of three SUTs (Type-5 Netgate device.) NIC cards placement into slots and NIC ports connectivity is following the testbed specification included in the next section.
+
 
+
== Inventory ==
+
 
+
=== Appliances ===
+
 
+
<pre>
+
1. Ixia PerfectStorm One Appliance
+
    - 1 * PS10GE4NG
+
        - Chassis: PS10GE4NG.
+
        - Motherboard: SuperMicro X11DPG-QT.
+
        - Processors: Quad-Core, Intel Processor.
+
        - HW accelerators: FPGA offload.
+
        - RAM Memory: 64GB.
+
        - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
+
        - Physical Interfaces: 4 * 10GE SFP+.
+
        - Operating System: Native IxOS.
+
</pre>
+
 
+
=== Servers ===
+
 
+
<pre>
+
1. Intel Xeon servers:
+
    - 20 * SuperMicro SYS-7049GP-TRT with Xeon Skylake processors.
+
        - Chassis: SuperMicro SYS-7049GP-TRT.
+
        - Motherboard: SuperMicro X11DPG-QT.
+
        - Processors: 2* Intel Platinum 8180 2.3 GHz.
+
        - RAM Memory: 16* 16GB DDR4-2666MHz.
+
        - Disks: 2* 1.6TB 6G SATA SSD.
+
2. Arm Cortex A-72 servers
+
    - 2 * Huawei TaiShan 2280.
+
        - Chassis: Huawei TaiShan 2280.
+
        - Processors: 1* hip07-d05 ~ 64* Arm Cortex-A72.
+
        - RAM Memory: 8* 16GB DDR4-2400MT/s.
+
        - Disks: 1* 4TB SATA HDD.
+
    - 3 * MACCHIATObin
+
        - Chassis: MACCHIATObin.
+
        - Processors: 1* Armada 8040 ~ 4* Arm Cortex-A72.
+
        - RAM Memory: 1* 16GB DDR4.
+
        - Disks: 1* 128GB(?) SATA SDD.
+
3. Intel Atom servers with Rangely processors.
+
    - 3 * Netgate XG-2758-1u
+
        - Chassis: Netgate XG-2758-1u
+
        - Processors: 1* Rangely (Atom) C2758 2.4 GHz
+
        - RAM Memory: 16GB ECC
+
        - Disks: 150 GB
+
</pre>
+
 
+
=== Network Interface Cards ===
+
 
+
<pre>
+
1. 10GE NICs
+
    - 14 * Intel® Ethernet Converged Network Adapter X710-DA4
+
    - 6 * Intel® Ethernet Converged Network Adapter X710-DA2
+
    - 6 * Intel® Ethernet Converged Network Adapter X520-DA2
+
2. 25GE NICs
+
    - 12 * Intel® Ethernet Network Adapter XXV710-DA2
+
3. 40GE NICs
+
    - 2 * Intel® Ethernet Converged Network Adapter XL710-QDA2
+
4. 100GE NICs
+
    - 4 * mcx556a-edat NICs (not on site yet, in transit)
+
</pre>
+
 
+
=== Pluggables and Cables ===
+
 
+
Pluggables:
+
 
+
<pre>
+
1. 10GE SFP+
+
    - 16 * Intel E10GSFPSR Ethernet SFP+ SR Optics
+
    - 80 * 10G SR optic (generic, "Intel" compatible branded)
+
2. 25GE SFP28
+
    - None
+
3. 40GE QSFP+
+
    - None
+
4. 100GE
+
    - 8 * mcp1600-c002 qsfp28 pluggables and cables (not on site yet, in transit)
+
</pre>
+
 
+
Standalone cables:
+
 
+
<pre>
+
1. 10GE
+
    - None
+
2. 25GE
+
    - None
+
3. 40GE QSFP+
+
    - 20 * Intel XLDACBL5 40G QSFP+ Passive DAC Cable
+
4. 100GE
+
    - None
+
</pre>
+
 
+
=== Other Network Cards ===
+
 
+
Any QATs?
+
 
+
== Installation Status ==
+
 
+
Lab installation status is tracked by LF IT team in [https://docs.google.com/document/d/16TdvGC73wuNQjkP355MTXRckv7yqnaxJkWwX7G7izEo/edit?ts=5b10411b#heading=h.dprb64shku8u FD.io Server Status].
+
 
+
== Server/Device Management and Naming ==
+
 
+
=== Server Management Requirements ===
+
 
+
Total of 20 SM SYS-7049GP-TRT servers are made available for FD.IO CSIT testbed.
+
For management purposes, each server must have following two ports connected to the management network:
+
 
+
* 1GE IPMI port
+
** IPMI - Intelligent Platform Management Interface.
+
** Required for access to embedded server management with WebUI, CLI, SNMPv3, IPMIv2.0, for firmware (BIOS) and OS updates.
+
* 1GE/10GE management port
+
** hostOS management port for general system management.
+
 
+
=== Server and Port Naming Convention ===
+
 
+
Following naming convention is used within this page to specify physical connectivity and wiring across defined CSIT testbeds:
+
 
+
<pre>
+
- testbedname: testbedN.
+
- hostname:
+
    - traffic-generator: tN-tgW.
+
    - system-under-testX: tN-sutX.
+
- portnames:
+
    - tN-tgW-cY/pZ.
+
    - tN-sutX-cY/pZ.
+
- where:
+
    - N - testbed number.
+
    - tgW - server acts as traffic-generator with W index.
+
    - sutX - server acts as system-under-test with X index.
+
    - Y - PCIe slot number denoting a NIC card number within the host.
+
        - Y=2,4,9 - slots connected to NUMA node 0.
+
        - Y=6,8,10 - slots connected to NUMA node 1.
+
    - Z - port number on the NIC card.
+
</pre>
+
 
+
=== Server Management - Addressing ===
+
 
+
Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a Management port, which are connected to two different VLANs.
+
 
+
<pre>
+
1. LOM (IPMI) VLAN:
+
    - Subnet: 10.30.50.0/24
+
    - Gateway: 10.30.50.1
+
    - Broadcast: 10.30.50.255
+
    - DNS1: 199.204.44.24
+
    - DNS2: 199.204.47.54
+
2. Management Vlan:
+
    - Subnet: 10.30.51.0/24
+
    - Gateway: 10.30.51.1
+
    - Broadcast: 10.30.51.255
+
    - DNS1: 199.204.44.24
+
    - DNS2: 199.204.47.54
+
</pre>
+
 
+
To access these hosts, an VPN connection is required.
+
 
+
=== LOM (IPMI) VLAN IP Addresses ===
+
 
+
<..>
+
 
+
=== Management VLAN IP Addresses ===
+
 
+
<..>
+
 
+
== Testbeds Specification - Target Build ==
+
 
+
=== Server/Ports Naming, NIC Placement ===
+
 
+
==== 1-Node Xeon ====
+
 
+
Each server in 1-node Xeon topology has its NIC cards placed, and NIC cards and ports indexed per following specification:
+
 
+
<pre>
+
- Server1 [Type-6]:
+
    - testbedname: testbed11.
+
    - hostname: s1-t11-sut1.
+
    - IPMI IP: 10.30.50.47
+
    - Host IP: 10.30.51.50
+
    - portnames:
+
        - s1-t11-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
+
        - s1-t11-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
+
        - s1-t11-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
+
        - s1-t11-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
+
        - s1-t11-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
+
        - s1-t11-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
+
        - s1-t11-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
+
        - s1-t11-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
+
- Server2 [Type-6]:
+
    - testbedname: testbed12.
+
    - hostname: s2-t12-sut1.
+
    - IPMI IP: 10.30.50.48
+
    - Host IP: 10.30.51.51
+
    - portnames:
+
        - s2-t12-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
+
        - s2-t12-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
+
        - s2-t12-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
+
        - s2-t12-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
+
        - s2-t12-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
+
        - s2-t12-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
+
        - s2-t12-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
+
        - s2-t12-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
+
</pre>
+
 
+
==== 2-Node Xeon ====
+
 
+
Each server in 2-node Xeon topology has its NIC cards placed, and NIC cards and ports indexed per following specification:
+
 
+
<pre>
+
- Server3 [Type-1]:
+
    - testbedname: testbed21.
+
    - hostname: s3-t21-sut1.
+
    - IPMI IP: 10.30.50.41
+
    - Host IP: 10.30.51.44
+
    - portnames:
+
        - s3-t21-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
+
        - s3-t21-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
+
        - s3-t21-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
+
        - s3-t21-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
+
        - s3-t21-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+
        - s3-t21-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+
        - s3-t21-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
+
        - s3-t21-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
+
- Server4 [Type-2]:
+
    - testbedname: testbed21.
+
    - hostname: s4-t21-tg1.
+
    - IPMI IP: 10.30.50.42
+
    - Host IP: 10.30.51.45
+
    - portnames:
+
        - s4-t21-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
+
        - s4-t21-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
+
        - s4-t21-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
+
        - s4-t21-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
+
        - s4-t21-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+
        - s4-t21-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+
        - s4-t21-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
+
        - s4-t21-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
+
- Server5 [Type-1]:
+
    - testbedname: testbed22.
+
    - hostname: s5-t22-sut1.
+
    - IPMI IP: 10.30.50.49
+
    - Host IP: 10.30.51.52
+
    - portnames:
+
        - s5-t22-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
+
        - s5-t22-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
+
        - s5-t22-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
+
        - s5-t22-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
+
        - s5-t22-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+
        - s5-t22-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+
        - s5-t22-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
+
        - s5-t22-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
+
- Server6 [Type-2]:
+
    - testbedname: testbed22.
+
    - hostname: s6-t22-tg1.
+
    - IPMI IP: 10.30.50.50
+
    - Host IP: 10.30.51.53
+
    - portnames:
+
        - s6-t22-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
+
        - s6-t22-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
+
        - s6-t22-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
+
        - s6-t22-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
+
        - s6-t22-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+
        - s6-t22-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+
        - s6-t22-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
+
        - s6-t22-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
+
- Server7 [Type-1]:
+
    - testbedname: testbed23.
+
    - hostname: s7-t23-sut1.
+
    - IPMI IP: 10.30.50.51
+
    - Host IP: 10.30.51.54
+
    - portnames:
+
        - s7-t23-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
+
        - s7-t23-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
+
        - s7-t23-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
+
        - s7-t23-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
+
        - s7-t23-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+
        - s7-t23-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+
        - s7-t23-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
+
        - s7-t23-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
+
- Server8 [Type-2]:
+
    - testbedname: testbed23.
+
    - hostname: s8-t23-tg1.
+
    - IPMI IP: 10.30.50.52
+
    - Host IP: 10.30.51.55
+
    - portnames:
+
        - s8-t23-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
+
        - s8-t23-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
+
        - s8-t23-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
+
        - s8-t23-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
+
        - s8-t23-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+
        - s8-t23-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+
        - s8-t23-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
+
        - s8-t23-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
+
- Server9 [Type-1]:
+
    - testbedname: testbed24.
+
    - hostname: s9-t24-sut1.
+
    - IPMI IP: 10.30.50.53
+
    - Host IP: 10.30.51.56
+
    - portnames:
+
        - s9-t24-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
+
        - s9-t24-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
+
        - s9-t24-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
+
        - s9-t24-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
+
        - s9-t24-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+
        - s9-t24-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+
        - s9-t24-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
+
        - s9-t24-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
+
- Server10 [Type-2]:
+
    - testbedname: testbed24.
+
    - hostname: s10-t24-tg1.
+
    - IPMI IP: 10.30.50.54
+
    - Host IP: 10.30.51.57
+
    - portnames:
+
        - s10-t24-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
+
        - s10-t24-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
+
        - s10-t24-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
+
        - s10-t24-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
+
        - s10-t24-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+
        - s10-t24-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+
        - s10-t24-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
+
        - s10-t24-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
+
</pre>
+
 
+
==== 3-Node Xeon ====
+
 
+
Each server in 3-node Xeon topology has its NIC cards placed, and NIC cards and ports indexed per following specification:
+
 
+
<pre>
+
- Server11 [Type-1]:
+
    - testbedname: testbed31.
+
    - hostname: s11-t31-sut1.
+
    - IPMI IP: 10.30.50.43
+
    - Host IP: 10.30.51.46
+
    - portnames:
+
        - s11-t31-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
+
        - s11-t31-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
+
        - s11-t31-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
+
        - s11-t31-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
+
        - s11-t31-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+
        - s11-t31-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+
        - s11-t31-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
+
        - s11-t31-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
+
- Server12 [Type-1]:
+
    - testbedname: testbed31.
+
    - hostname: s12-t31-sut2.
+
    - IPMI IP: 10.30.50.44
+
    - Host IP: 10.30.51.47
+
    - portnames:
+
        - s12-t31-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
+
        - s12-t31-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
+
        - s12-t31-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
+
        - s12-t31-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
+
        - s12-t31-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+
        - s12-t31-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+
        - s12-t31-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
+
        - s12-t31-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
+
- Server13 [Type-2]:
+
    - testbedname: testbed31.
+
    - hostname: s13-t31-tg1.
+
    - IPMI IP: 10.30.50.45
+
    - Host IP: 10.30.51.48
+
    - portnames:
+
        - s13-t31-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
+
        - s13-t31-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
+
        - s13-t31-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
+
        - s13-t31-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
+
        - s13-t31-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+
        - s13-t31-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+
        - s13-t31-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
+
        - s13-t31-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
+
- Server14 [Type-1]:
+
    - testbedname: testbed32.
+
    - hostname: s14-t32-sut1.
+
    - IPMI IP: 10.30.50.55
+
    - Host IP: 10.30.51.58
+
    - portnames:
+
        - s14-t32-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
+
        - s14-t32-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
+
        - s14-t32-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
+
        - s14-t32-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
+
        - s14-t32-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+
        - s14-t32-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+
        - s14-t32-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
+
        - s14-t32-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
+
- Server15 [Type-1]:
+
    - testbedname: testbed32.
+
    - hostname: s15-t32-sut2.
+
    - IPMI IP: 10.30.50.56
+
    - Host IP: 10.30.51.59
+
    - portnames:
+
        - s15-t32-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
+
        - s15-t32-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
+
        - s15-t32-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
+
        - s15-t32-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
+
        - s15-t32-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+
        - s15-t32-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+
        - s15-t32-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
+
        - s15-t32-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
+
- Server16 [Type-2]:
+
    - testbedname: testbed32.
+
    - hostname: s16-t32-tg1.
+
    - IPMI IP: 10.30.50.57
+
    - Host IP: 10.30.51.60
+
    - portnames:
+
        - s16-t32-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
+
        - s16-t32-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
+
        - s16-t32-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
+
        - s16-t32-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
+
        - s16-t32-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+
        - s16-t32-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+
        - s16-t32-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
+
        - s16-t32-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
+
</pre>
+
 
+
==== 3-Node Arm ====
+
 
+
Note: Server19 (TG) is shared between testbed33 & testbed34
+
 
+
<pre>
+
- Server17 [Type-3]:
+
    - testbedname: testbed33.
+
    - hostname: s17-t33-sut1.
+
    - IPMI IP: 10.30.50.36
+
    - Host IP: 10.30.51.36
+
    - portnames:
+
        - s17-t33-sut1-ca/p1 - 10GE-port1 82599-2p10GE.
+
        - s17-t33-sut1-ca/p2 - 10GE-port2 82599-2p10GE.
+
        - s17-t33-sut1-c2/p1 - 25GE-port1 cx4-2p25GE.
+
        - s17-t33-sut1-c2/p2 - 25GE-port2 cx4-2p25GE.
+
- Server18 [Type-3]:
+
    - testbedname: testbed33.
+
    - hostname: s18-t33-sut2.
+
    - IPMI IP: 10.30.50.37
+
    - Host IP: 10.30.51.37
+
    - portnames:
+
        - s18-t33-sut2-ca/p1 - 10GE-port1 82599-2p10GE.
+
        - s18-t33-sut2-ca/p2 - 10GE-port2 82599-2p10GE.
+
        - s18-t33-sut2-c2/p1 - 25GE-port1 cx4-2p25GE.
+
        - s18-t33-sut2-c2/p2 - 25GE-port2 cx4-2p25GE.
+
- Server19 [Type-2]:
+
    - testbedname: testbed33.
+
    - hostname: s19-t33t34-tg1.
+
    - IPMI IP: 10.30.50.46
+
    - Host IP: 10.30.51.49
+
    - portnames:
+
        - s19-t33t34-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
+
        - s19-t33t34-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
+
        - s19-t33t34-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
+
        - s19-t33t34-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
+
        - s19-t33t34-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+
        - s19-t33t34-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+
- Server20 [Type-4]:
+
    - testbedname: testbed34.
+
    - hostname: s20-t34-sut1.
+
    - IPMI IP: N/A
+
    - Host IP: 10.30.51.41
+
    - portnames:
+
        - s20-t34-sut1-ca/p1 - 10GE-port1 Marvell.
+
        - s20-t34-sut1-ca/p2 - 10GE-port2 Marvell.
+
- Server21 [Type-4]:
+
    - testbedname: testbed34.
+
    - hostname: s21-t34-sut2.
+
    - IPMI IP: N/A
+
    - Host IP: 10.30.51.42
+
    - portnames:
+
        - s21-t34-sut2-ca/p1 - 10GE-port1 Marvell.
+
        - s21-t34-sut2-ca/p2 - 10GE-port2 Marvell.
+
</pre>
+
 
+
==== TCP/IP and L47 ====
+
 
+
Each server (appliance) in 2-node TCP/IP topology has its NIC cards placed, and NIC cards and ports indexed per following specification:
+
 
+
<pre>
+
- Server25 [Type-8]:
+
    - testbedname: testbed25.
+
    - hostname: s25-t25-sut1.
+
    - IPMI IP: 10.30.50.58
+
    - Host IP: 10.30.51.61
+
    - portnames:
+
        - s25-t25-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
+
        - s25-t25-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
+
        - s25-t25-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
+
        - s25-t25-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
+
- Server26 [Type-7]:
+
    - testbedname: testbed25.
+
    - hostname: s26-t25-tg1.
+
    - IPMI IP: 10.30.50.59
+
    - Host IP: 10.30.51.62
+
    - portnames:
+
        - s26-t25-tg1-p1 - 10GE-port1.
+
        - s26-t25-tg1-p2 - 10GE-port2.
+
        - s26-t25-tg1-p3 - 10GE-port3.
+
        - s26-t25-tg1-p4 - 10GE-port4.
+
</pre>
+
 
+
==== 3-Node Atom ====
+
 
+
Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
+
 
+
<pre>
+
- Server22 [Type-5]:
+
    - testbedname: testbed35.
+
    - hostname: s22-t35-sut1 (vex-yul-rot-netgate-1).
+
    - IPMI IP: 10.30.51.29 - screen -r /dev/ttyUSB0
+
    - Host IP: 10.30.51.9
+
    - portnames:
+
        - s22-t35-sut1-p1 - 10GE-port1 ix0 82599.
+
        - s22-t35-sut1-p2 - 10GE-port2 ix1 82599.
+
    - 1GB ports (tbd)
+
- Server23 [Type-5]:
+
    - testbedname: testbed35.
+
    - hostname: s23-t35-sut2 (vex-yul-rot-netgate-2).
+
    - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB1
+
    - Host IP: 10.30.51.10
+
    - portnames:
+
        - s23-t35-sut1-p1 - 10GE-port1 ix0 82599.
+
        - s23-t35-sut1-p2 - 10GE-port2 ix1 82599.
+
    - 1GB ports (tbd)
+
- Server24 [Type-5]:
+
    - testbedname: testbed35.
+
    - hostname: s24-t35-sut3 (vex-yul-rot-netgate-3).
+
    - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB2
+
    - Host IP: 10.30.51.11
+
    - portnames:
+
        - s24-t35-sut1-p1 - 10GE-port1 ix0 82599.
+
        - s24-t35-sut1-p2 - 10GE-port2 ix1 82599.
+
    - 1GB ports (tbd)
+
</pre>
+
 
+
=== Physical Connectivity within Testbeds ===
+
 
+
==== 1-Node Xeon ====
+
 
+
Two 1-Node testbeds are constructed by connecting 2 Xeon servers using below specification:
+
 
+
<pre>
+
- testbed11:
+
    - ring1 10GE-ports x710-4p10GE:
+
        - s1-t11-sut1-c2/p1 to s1-t11-sut1-c4/p1.
+
    - ring2 10GE-ports x710-4p10GE:
+
        - s1-t11-sut1-c2/p2 to s1-t11-sut1-c4/p2.
+
    - ring3 10GE-ports x710-4p10GE:
+
        - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
+
    - ring4 10GE-ports x710-4p10GE:
+
        - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
+
- testbed12:
+
    - ring1 10GE-ports x710-4p10GE:
+
        - s2-t12-sut1-c2/p1 to s2-t12-sut1-c4/p1.
+
    - ring2 10GE-ports x710-4p10GE:
+
        - s2-t12-sut1-c2/p2 to s2-t12-sut1-c4/p2.
+
    - ring3 10GE-ports x710-4p10GE:
+
        - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
+
    - ring4 10GE-ports x710-4p10GE:
+
        - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
+
</pre>
+
 
+
==== 2-Node Xeon ====
+
 
+
Four 2-Node testbeds are constructed by connecting 8 Xeon servers using below specification:
+
 
+
<pre>
+
- testbed21:
+
    - ring1 10GE-ports x710-4p10GE on SUT:
+
        - s4-t21-tg1-c2/p1 to s3-t21-sut1-c2/p1.
+
        - s3-t21-sut1-c2/p2 to s4-t21-tg1-c2/p2.
+
    - ring2 10GE-ports x710-4p10GE on SUT:
+
        - s4-t21-tg1-c2/p3 to s3-t21-sut1-c2/p3.
+
        - s3-t21-sut1-c2/p4 to s4-t21-tg1-c2/p4.
+
    - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
+
        - s4-t21-tg1-c4/p1 to s3-t21-sut1-c4/p1.
+
        - s3-t21-sut1-c4/p2 to s4-t21-tg1-c4/p2.
+
    - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
+
        - s4-t21-tg1-c9/p1 to s3-t21-sut1-c9/p1.
+
        - s3-t21-sut1-c9/p2 to s4-t21-tg1-c9/p2.
+
    - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
+
        - s4-t21-tg1-c10/p1 to s4-t21-tg1-c10/p2.
+
        - s4-t21-tg1-c10/p3 to s4-t21-tg1-c10/p4.
+
- testbed22:
+
    - ring1 10GE-ports x710-4p10GE on SUT:
+
        - s6-t22-tg1-c2/p1 to s5-t22-sut1-c2/p1.
+
        - s5-t22-sut1-c2/p2 to s6-t22-tg1-c2/p2.
+
    - ring2 10GE-ports x710-4p10GE on SUT:
+
        - s6-t22-tg1-c2/p3 to s5-t22-sut1-c2/p3.
+
        - s5-t22-sut1-c2/p4 to s6-t22-tg1-c2/p4.
+
    - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
+
        - s6-t22-tg1-c4/p1 to s5-t22-sut1-c4/p1.
+
        - s5-t22-sut1-c4/p2 to s6-t22-tg1-c4/p2.
+
    - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
+
        - t22-tg1-c9/p1 to s5-t22-sut1-c9/p1.
+
        - s5-t22-sut1-c9/p2 to s6-t22-tg1-c9/p2.
+
    - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
+
        - s6-t22-tg1-c10/p1 to s6-t22-tg1-c10/p2.
+
        - s6-t22-tg1-c10/p3 to s6-t22-tg1-c10/p4.
+
- testbed23:
+
    - ring1 10GE-ports x710-4p10GE on SUT:
+
        - s8-t23-tg1-c2/p1 to s7-t23-sut1-c2/p1.
+
        - s7-t23-sut1-c2/p2 to s8-t23-tg1-c2/p2.
+
    - ring2 10GE-ports x710-4p10GE on SUT:
+
        - s8-t23-tg1-c2/p3 to s7-t23-sut1-c2/p3.
+
        - s7-t23-sut1-c2/p4 to s8-t23-tg1-c2/p4.
+
    - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
+
        - s8-t23-tg1-c4/p1 to s7-t23-sut1-c4/p1.
+
        - s7-t23-sut1-c4/p2 to s8-t23-tg1-c4/p2.
+
    - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
+
        - s8-t23-tg1-c9/p1 to s7-t23-sut1-c9/p1.
+
        - s7-t23-sut1-c9/p2 to s8-t23-tg1-c9/p2.
+
    - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
+
        - s8-t23-tg1-c10/p1 to s8-t23-tg1-c10/p2.
+
        - s8-t23-tg1-c10/p3 to s8-t23-tg1-c10/p4.
+
- testbed24:
+
    - ring1 10GE-ports x710-4p10GE on SUT:
+
        - s10-t24-tg1-c2/p1 to s9-t24-sut1-c2/p1.
+
        - s9-t24-sut1-c2/p2 to s10-t24-tg1-c2/p2.
+
    - ring2 10GE-ports x710-4p10GE on SUT:
+
        - s10-t24-tg1-c2/p3 to s9-t24-sut1-c2/p3.
+
        - s9-t24-sut1-c2/p4 to s10-t24-tg1-c2/p4.
+
    - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
+
        - s10-t24-tg1-c4/p1 to s9-t24-sut1-c4/p1.
+
        - s9-t24-sut1-c4/p2 to s10-t24-tg1-c4/p2.
+
    - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
+
        - s10-t24-tg1-c9/p1 to s9-t24-sut1-c9/p1.
+
        - s9-t24-sut1-c9/p2 to s10-t24-tg1-c9/p2.
+
    - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
+
        - s10-t24-tg1-c10/p1 to s10-t24-tg1-c10/p2.
+
        - s10-t24-tg1-c10/p3 to s10-t24-tg1-c10/p4.
+
</pre>
+
 
+
==== 3-Node Xeon ====
+
 
+
Two 3-Node testbeds are constructed by connecting 6 Xeon servers using below specification:
+
 
+
<pre>
+
- testbed31:
+
    - ring1 10GE-ports x710-4p10GE on SUTs:
+
        - s13-t31-tg1-c2/p1 to s11-t31-sut1-c2/p1.
+
        - s11-t31-sut1-c2/p2 to s12-t31-sut2-c2/p2.
+
        - s12-t31-sut2-c2/p1 to s13-t31-tg1-c2/p2.
+
    - ring2 10GE-ports x710-4p10GE on SUT:
+
        - s13-t31-tg1-c2/p3 to s11-t31-sut1-c2/p3.
+
        - s11-t31-sut1-c2/p4 to s12-t31-sut2-c2/p4.
+
        - s12-t31-sut2-c2/p3 to s13-t31-tg1-c2/p4.
+
    - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
+
        - s13-t31-tg1-c4/p1 to s11-t31-sut1-c4/p1.
+
        - s11-t31-sut1-c4/p2 to s12-t31-sut2-c4/p2.
+
        - s12-t31-sut2-c4/p1 to s13-t31-tg1-c4/p2.
+
    - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
+
        - s13-t31-tg1-c9/p1 to s11-t31-sut1-c9/p1.
+
        - s11-t31-sut1-c9/p2 to s12-t31-sut2-c9/p2.
+
        - s12-t31-sut2-c9/p1 to s13-t31-tg1-c9/p2.
+
    - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
+
        - s13-t31-tg1-c10/p1 to s13-t31-tg1-c10/p2.
+
        - s13-t31-tg1-c10/p3 to s13-t31-tg1-c10/p4.
+
- testbed32:
+
    - ring1 10GE-ports x710-4p10GE on SUTs:
+
        - s16-t32-tg1-c2/p1 to s14-t32-sut1-c2/p1.
+
        - s14-t32-sut1-c2/p2 to s15-t32-sut2-c2/p2.
+
        - s15-t32-sut2-c2/p1 to s16-t32-tg1-c2/p2.
+
    - ring2 10GE-ports x710-4p10GE on SUT:
+
        - s16-t32-tg1-c2/p3 to s14-t32-sut1-c2/p3.
+
        - s14-t32-sut1-c2/p4 to s15-t32-sut2-c2/p4.
+
        - s15-t32-sut2-c2/p3 to s16-t32-tg1-c2/p4.
+
    - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
+
        - s16-t32-tg1-c4/p1 to s14-t32-sut1-c4/p1.
+
        - s14-t32-sut1-c4/p2 to s15-t32-sut2-c4/p2.
+
        - s15-t32-sut2-c4/p1 to s16-t32-tg1-c4/p2.
+
    - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
+
        - s16-t32-tg1-c9/p1 to s14-t32-sut1-c9/p1.
+
        - s14-t32-sut1-c9/p2 to s15-t32-sut2-c9/p2.
+
        - s15-t32-sut2-c9/p1 to s16-t32-tg1-c9/p2.
+
    - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
+
        - s16-t32-tg1-c10/p1 to s16-t32-tg1-c10/p2.
+
        - s16-t32-tg1-c10/p3 to s16-t32-tg1-c10/p4.
+
</pre>
+
 
+
==== 3-Node Arm ====
+
 
+
One 3-Node testbed is constructed by connecting 3 Arm servers using below specification:
+
 
+
<pre>
+
- testbed33:
+
    - ring1 10GE-ports 82599-2p10GE on SUTs:
+
        - t33t34-tg1-c2/p1 - t33-sut1-ca/p1.
+
        - t33-sut1-ca/p2 - t33-sut2-ca/p1.
+
        - t33-sut2-ca/p2 - t33t34-tg1-c2/p2.
+
    - ring2 25GE-ports cx4-2p25GE on SUTs:
+
        - t33t34-tg1-c4/p1 - t33-sut1-c2/p1.
+
        - t33-sut1-c2/p2 - t33-sut2-c2/p1.
+
        - t33-sut2-c2/p2 - t33t34-tg1-c4/p2.
+
- testbed34:
+
    - ring1 10GE-ports Marvell on SUTs:
+
        - t33t34-tg1-c2/p3 - t34-sut1-ca/p1.
+
        - t34-sut1-ca/p2 - t34-sut2-ca/p1.
+
        - t34-sut2-ca/p2 - t33t34-tg1-c2/p4.
+
</pre>
+
 
+
==== TCP/IP and L47 ====
+
 
+
One 2-Node TCP/IP testbed is constructed by connecting Ixia PSOne and 1 Xeon server using below specification:
+
 
+
<pre>
+
- testbed25:
+
    - link1 10GE-port x710-4p10GE on SUT:
+
        - t25-tg1-p1 to t25-sut1-c2/p1.
+
    - link2 10GE-port x710-4p10GE on SUT:
+
        - t25-tg1-p2 to t25-sut1-c2/p2.
+
    - link3 10GE-port x710-4p10GE on SUT:
+
        - t25-tg1-p3 to t25-sut1-c2/p3.
+
    - link4 10GE-port x710-4p10GE on SUT:
+
        - t25-tg1-p4 to t25-sut1-c2/p4.
+
</pre>
+
 
+
==== 3-Node Atom ====
+
 
+
<..>
+
 
+
=== Host OS and configuration ===
+
 
+
 
+
====Boot Feature====
+
 
+
  |  Quiet Boot                                [Enabled]              |Boot option                  |
+
  |                                                                    |                            |
+
  |  Option ROM Messages                      [Force BIOS]            |                            |
+
  |  Bootup NumLock State                      [On]                    |                            |
+
  |  Wait For "F1" If Error                    [Enabled]              |                            |
+
  |  INT19 Trap Response                      [Immediate]            |                            |
+
  |  Re-try Boot                              [Disabled]              |                            |
+
  |  Install Windows 7 USB support            [Disabled]              |                            |
+
  |  Port 61h Bit-4 Emulation                  [Disabled]              |                            |
+
  |                                                                    |                            |
+
  |  Power Configuration                                              |                            |
+
  |  Watch Dog Function                        [Disabled]              |                            |
+
  |  Restore on AC Power Loss                  [Last State]            |                            |
+
  |  Power Button Function                    [Instant Off]          |                            |
+
  |  Throttle on Power Fail                    [Disabled]              |                            |
+
 
+
====CPU Configuration====
+
 
+
  |  Processor Configuration                                          |Enables Hyper Threading      |
+
  |  --------------------------------------------------                |(Software Method to          |
+
  |  Processor BSP Revision                    50654 - SKX H0          |Enable/Disable Logical      |
+
  |  Processor Socket                          CPU1      |  CPU2      |Processor threads.          |
+
  |  Processor ID                              00050654* |  000506...  |                            |
+
  |  Processor Frequency                      2.500GHz  |  2.500GHz  |                            |
+
  |  Processor Max Ratio                            19H  |  19H        |                            |
+
  |  Processor Min Ratio                            0AH  |  0AH        |                            |
+
  |  Microcode Revision                        02000030                |                            |
+
  |  L1 Cache RAM                                  64KB  |      64KB  |                            |
+
  |  L2 Cache RAM                                1024KB  |    1024KB  |                            |
+
  |  L3 Cache RAM                              39424KB  |  39424KB  |                            |
+
  |  Processor 0 Version                                              |                            |
+
  |  Intel(R) Xeon(R) Platinum 8180 CPU @ 2.50GHz                      |                            |
+
  |  Processor 1 Version                                              |                            |
+
  |  Intel(R) Xeon(R) Platinum 8180 CPU @ 2.50GHz                      |                            |
+
  |                                                                    |                            |
+
  |  Hyper-Threading [ALL]                    [Enable]                |                            |
+
  |  Core Disable Bitmap(Hex)                  0                      |                            |
+
  |  Execute Disable Bit                      [Enable]                |                            |
+
  |  Intel Virtualization Technology          [Enable]                |                            |
+
  |  PPIN Control                              [Unlock/Enable]        |                            |
+
  |  Hardware Prefetcher                      [Enable]                |                            |
+
  |  Adjacent Cache Prefetch                  [Enable]                |                            |
+
  |  DCU Streamer Prefetcher                  [Enable]                |                            |
+
  |  DCU IP Prefetcher                        [Enable]                |                            |
+
  |  LLC Prefetch                              [Disable]              |                            |
+
  |  Extended APIC                            [Disable]              |                            |
+
  |  AES-NI                                    [Enable]                |                            |
+
  |> Advanced Power Management Configuration                          |                            |
+
 
+
=====Advanced Power Management Configuration=====
+
 
+
  |  Advanced Power Management Configuration                          |Switch CPU Power Management  |
+
  |  --------------------------------------------------                |profile                      |
+
  |  Power Technology                          [Custom]                |                            |
+
  |  Power Performance Tuning                  [BIOS Controls EPB]    |                            |
+
  |  ENERGY_PERF_BIAS_CFG mode                [Maximum Performance]  |                            |
+
  |> CPU P State Control                                              |                            |
+
  |> Hardware PM State Control                                        |                            |
+
  |> CPU C State Control                                              |                            |
+
  |> Package C State Control                                          |                            |
+
  |> CPU T State Control                                              |                            |
+
 
+
======CPU P State Control======
+
 
+
  |  CPU P State Control                                              |Enable/Disable EIST          |
+
  |                                                                    |(P-States)                  |
+
  |  SpeedStep (Pstates)                      [Disable]              |                            |
+
  |  EIST PSD Function                        [HW_ALL]                |                            |
+
 
+
======Hardware PM State Control======
+
 
+
  |  Hardware PM State Control                                        |Disable: Hardware chooses a  |
+
  |                                                                    |P-state based on OS Request  |
+
  |  Hardware P-States                        [Disable]              |(Legacy P-States)            |
+
  |                                                                    |Native Mode:Hardware        |
+
  |                                                                    |chooses a P-state based on  |
+
  |                                                                    |OS guidance                  |
+
  |                                                                    |Out of Band Mode:Hardware    |
+
  |                                                                    |autonomously chooses a      |
+
  |                                                                    |P-state (no OS guidance)    |
+
 
+
======CPU C State Control======
+
 
+
  |  CPU C State Control                                              |Autonomous Core C-State      |
+
  |                                                                    |Control                      |
+
  |  Autonomous Core C-State                  [Disable]              |                            |
+
  |  CPU C6 report                            [Disable]              |                            |
+
  |  Enhanced Halt State (C1E)                [Disable]              |                            |
+
 
+
======Package C State Control======
+
 
+
  |  Package C State Control                                          |Package C State limit        |
+
  |                                                                    |                            |
+
  |  Package C State                          [C0/C1 state]          |                            |
+
 
+
======CPU T State Control======
+
 
+
  |  CPU T State Control                                              |Enable/Disable Software      |
+
  |                                                                    |Controlled T-States          |
+
  |  Software Controlled T-States              [Disable]              |                            |
+
 
+
=====Chipset Configuration=====
+
 
+
  |  WARNING: Setting wrong values in below sections may cause        |North Bridge Parameters      |
+
  |          system to malfunction.                                  |                            |
+
  |> North Bridge                                                      |                            |
+
  |> South Bridge                                                      |                            |
+
 
+
======North Bridge======
+
 
+
  |> UPI Configuration                                                |Displays and provides        |
+
  |> Memory Configuration                                              |option to change the UPI    |
+
  |> IIO Configuration                                                |Settings                    |
+
 
+
======UPI Configuration======
+
 
+
  |  UPI Configuration                                                |Choose Topology Precedence  |
+
  |  --------------------------------------------------                |to degrade features if      |
+
  |  Number of CPU                            2                      |system options are in        |
+
  |  Number of Active UPI Link                3                      |conflict or choose Feature  |
+
  |  Current UPI Link Speed                    Fast                    |Precedence to degrade        |
+
  |  Current UPI Link Frequency                10.4 GT/s              |topology if system options  |
+
  |  UPI Global MMIO Low Base / Limit          90000000 / FBFFFFFF    |are in conflict.            |
+
  |  UPI Global MMIO High Base / Limit        0000000000000000 / ...  |                            |
+
  |  UPI Pci-e Configuration Base / Size      80000000 / 10000000    |                            |
+
  |  Degrade Precedence                        [Topology Precedence]  |                            |
+
  |  Link L0p Enable                          [Disable]              |                            |
+
  |  Link L1 Enable                            [Disable]              |                            |
+
  |  IO Directory Cache (IODC)                [Auto]                  |                            |
+
  |  SNC                                      [Disable]              |                            |
+
  |  XPT Prefetch                              [Disable]              |                            |
+
  |  KTI Prefetch                              [Enable]                |                            |
+
  |  Local/Remote Threshold                    [Auto]                  |                            |
+
  |  Stale AtoS                                [Disable]              |                            |
+
  |  LLC dead line alloc                      [Enable]                |                            |
+
  |  Isoc Mode                                [Auto]                  |                            |
+
 
+
======Memory Configuration======
+
 
+
  |                                                                    |POR - Enforces Plan Of      |
+
  |  --------------------------------------------------                |Record restrictions for      |
+
  |  Integrated Memory Controller (iMC)                                |DDR4 frequency and voltage  |
+
  |  --------------------------------------------------                |programming. Disable -      |
+
  |                                                                    |Disables this feature.      |
+
  |  Enforce POR                              [Disable]              |                            |
+
  |  Memory Frequency                          [2666]                  |                            |
+
  |  Data Scrambling for NVMDIMM              [Auto]                  |                            |
+
  |  Data Scrambling for DDR4                  [Auto]                  |                            |
+
  |  tCCD_L Relaxation                        [Auto]                  |                            |
+
  |  Memory tRWSR Relaxation                  [Enable]                |                            |
+
  |  2X REFRESH                                [Auto]                  |                            |
+
  |  Page Policy                              [Auto]                  |                            |
+
  |  IMC Interleaving                          [2-way Interleave]      |                            |
+
  |> Memory Topology                                                  |                            |
+
  |> Memory RAS Configuration                                          |                            |
+
 
+
======IIO Configuration======
+
 
+
  |  IIO Configuration                                                |Expose IIO DFX devices and  |
+
  |  --------------------------------------------------                |other CPU devices like PMON  |
+
  |                                                                    |                            |
+
  |  EV DFX Features                          [Disable]              |                            |
+
  |> CPU1 Configuration                                                |                            |
+
  |> CPU2 Configuration                                                |                            |
+
  |> IOAT Configuration                                                |                            |
+
  |> Intel. VT for Directed I/O (VT-d)                                |                            |
+
  |> Intel. VMD technology                                            |                            |
+
  |                                                                    |                            |
+
  |  IIO-PCIE Express Global Options                                  |                            |
+
  |  ========================================                          |                            |
+
  |  PCI-E Completion Timeout Disable          [No]                    |                            |
+
 
+
======CPU1 Configuration======
+
 
+
  |  IOU0 (IIO PCIe Br1)                      [Auto]                  |Selects PCIe port            |
+
  |  IOU1 (IIO PCIe Br2)                      [Auto]                  |Bifurcation for selected    |
+
  |  IOU2 (IIO PCIe Br3)                      [Auto]                  |slot(s)                      |
+
  |> CPU1 SLOT2 PCI-E 3.0 X16                                          |                            |
+
  |> CPU1 SLOT4 PCI-E 3.0 X16                                          |                            |
+
  |> CPU1 SLOT9 PCI-E 3.0 X16                                          |                            |
+
 
+
======CPU2 Configuration======
+
 
+
  |  IOU0 (IIO PCIe Br1)                      [Auto]                  |Selects PCIe port            |
+
  |  IOU1 (IIO PCIe Br2)                      [Auto]                  |Bifurcation for selected    |
+
  |  IOU2 (IIO PCIe Br3)                      [Auto]                  |slot(s)                      |
+
  |> CPU2 SLOT6 PCI-E 3.0 X16                                          |                            |
+
  |> CPU2 SLOT8 PCI-E 3.0 X16                                          |                            |
+
  |> CPU2 SLOT10 PCI-E 3.0 X16                                        |                            |
+
 
+
=====South Bridge=====
+
 
+
  |                                                                    |Enables Legacy USB support.  |
+
  |  USB Module Version                        17                      |AUTO option disables legacy  |
+
  |                                                                    |support if no USB devices    |
+
  |  USB Devices:                                                      |are connected. DISABLE      |
+
  |        1 Keyboard, 1 Mouse, 1 Hub                                  |option will keep USB        |
+
  |                                                                    |devices available only for  |
+
  |  Legacy USB Support                        [Enabled]              |EFI applications.            |
+
  |  XHCI Hand-off                            [Disabled]              |                            |
+
  |  Port 60/64 Emulation                      [Enabled]              |                            |
+
  |  PCIe PLL SSC                              [Disable]              |                            |
+
  |  Real USB Wake Up                          [Enabled]              |                            |
+
  |  Front USB Wake Up                        [Enabled]              |                            |
+
  |                                                                    |                            |
+
  |  Azalia                                    [Auto]                  |                            |
+
  |    Azalia PME Enable                      [Disabled]              |                            |
+
 
+
====PCIe/PCI/PnP Configuration====
+
 
+
  |  PCI Bus Driver Version                    A5.01.12                |Enables or Disables 64bit    |
+
  |                                                                    |capable Devices to be        |
+
  |  PCI Devices Common Settings:                                      |Decoded in Above 4G Address  |
+
  |  Above 4G Decoding                        [Enabled]              |Space (Only if System        |
+
  |  SR-IOV Support                            [Enabled]              |Supports 64 bit PCI          |
+
  |  MMIO High Base                            [56T]                  |Decoding).                  |
+
  |  MMIO High Granularity Size                [256G]                  |                            |
+
  |  Maximum Read Request                      [Auto]                  |                            |
+
  |  MMCFG Base                                [2G]                    |                            |
+
  |  NVMe Firmware Source                      [Vendor Defined Fi...]  |                            |
+
  |  VGA Priority                              [Onboard]              |                            |
+
  |  CPU1 SLOT2 PCI-E 3.0 X16 OPROM            [Legacy]                |                            |
+
  |  CPU1 SLOT4 PCI-E 3.0 X16 OPROM            [Legacy]                |                            |
+
  |  CPU2 SLOT6 PCI-E 3.0 X16 OPROM            [Legacy]                |                            |
+
  |  CPU2 SLOT8 PCI-E 3.0 X16 OPROM            [Legacy]                |                            |
+
  |  CPU1 SLOT9 PCI-E 3.0 X16 OPROM            [Legacy]                |                            |
+
  |  CPU2 SLOT10 PCI-E 3.0 X16 OPROM          [Legacy]                |                            |
+
  |  CPU2 SLOT11 PCI-E 3.0 X4(IN X8) OPROM    [Legacy]                |                            |
+
  |  M.2 CONNECTOR OPROM                      [Legacy]                |                            |
+
  |  Onboard LAN1 Option ROM                  [Legacy]                |                            |
+
  |  Onboard LAN2 Option ROM                  [Disabled]              |                            |
+
  |  Onboard Video Option ROM                  [Legacy]                |                            |
+
  |> Network Stack Configuration                                      |                            |
+
 
+
====ACPI Settings====
+
 
+
  |  ACPI Settings                                                    |Enable or Disable Non        |
+
  |                                                                    |uniform Memory Access        |
+
  |  NUMA                                      [Enabled]              |(NUMA).                      |
+
  |  WHEA Support                              [Enabled]              |                            |
+
  |  High Precision Event Timer                [Enabled]              |                            |
+
  |  ACPI Sleep State                          [S3 (Suspend to RAM)]  |                            |
+
 
+
 
+
  # dmidecode 3.1
+
  Getting SMBIOS data from sysfs.
+
  SMBIOS 3.1.1 present.
+
  Table at 0x000E89C0.
+
 
+
  Handle 0x0000, DMI type 0, 26 bytes
+
  BIOS Information
+
        Vendor: American Megatrends Inc.
+
        Version: 2.0
+
        Release Date: 11/29/2017
+
        Address: 0xF0000
+
        Runtime Size: 64 kB
+
        ROM Size: 64 MB
+
        Characteristics:
+
                PCI is supported
+
                BIOS is upgradeable
+
                BIOS shadowing is allowed
+
                Boot from CD is supported
+
                Selectable boot is supported
+
                BIOS ROM is socketed
+
                EDD is supported
+
                5.25"/1.2 MB floppy services are supported (int 13h)
+
                3.5"/720 kB floppy services are supported (int 13h)
+
                3.5"/2.88 MB floppy services are supported (int 13h)
+
                Print screen service is supported (int 5h)
+
                Serial services are supported (int 14h)
+
                Printer services are supported (int 17h)
+
                ACPI is supported
+
                USB legacy is supported
+
                BIOS boot specification is supported
+
                Targeted content distribution is supported
+
                UEFI is supported
+
        BIOS Revision: 5.12
+
 
+
  Handle 0x0001, DMI type 1, 27 bytes
+
  System Information
+
        Manufacturer: Supermicro
+
        Product Name: SYS-7049GP-TRT
+
        Version: 0123456789
+
        Serial Number: S291427X8332242
+
        UUID: 00000000-0000-0000-0000-AC1F6B8A8DB6
+
        Wake-up Type: Power Switch
+
        SKU Number: To be filled by O.E.M.
+
        Family: To be filled by O.E.M.
+
 
+
  Handle 0x0002, DMI type 2, 15 bytes
+
  Base Board Information
+
        Manufacturer: Supermicro
+
        Product Name: X11DPG-QT
+
        Version: 1.02
+
        Serial Number: VM183S014930
+
        Asset Tag: To be filled by O.E.M.
+
        Features:
+
                Board is a hosting board
+
                Board is replaceable
+
        Location In Chassis: To be filled by O.E.M.
+
        Chassis Handle: 0x0003
+
        Type: Motherboard
+
        Contained Object Handles: 0
+
 
+
  Handle 0x0003, DMI type 3, 22 bytes
+
  Chassis Information
+
        Manufacturer: Supermicro
+
        Type: Other
+
        Lock: Not Present
+
        Version: 0123456789
+
        Serial Number: C7470KH06A20167
+
        Asset Tag: To be filled by O.E.M.
+
        Boot-up State: Safe
+
        Power Supply State: Safe
+
        Thermal State: Safe
+
        Security Status: None
+
        OEM Information: 0x00000000
+
 
+
  Handle 0x0050, DMI type 4, 48 bytes
+
  Processor Information
+
        Socket Designation: CPU1
+
        Type: Central Processor
+
        Family: Xeon
+
        Manufacturer: Intel(R) Corporation
+
        ID: 54 06 05 00 FF FB EB BF
+
        Signature: Type 0, Family 6, Model 85, Stepping 4
+
        Flags:
+
                FPU (Floating-point unit on-chip)
+
                VME (Virtual mode extension)
+
                DE (Debugging extension)
+
                PSE (Page size extension)
+
                TSC (Time stamp counter)
+
                MSR (Model specific registers)
+
                PAE (Physical address extension)
+
                MCE (Machine check exception)
+
                CX8 (CMPXCHG8 instruction supported)
+
                APIC (On-chip APIC hardware supported)
+
                SEP (Fast system call)
+
                MTRR (Memory type range registers)
+
                PGE (Page global enable)
+
                MCA (Machine check architecture)
+
                CMOV (Conditional move instruction supported)
+
                PAT (Page attribute table)
+
                PSE-36 (36-bit page size extension)
+
                CLFSH (CLFLUSH instruction supported)
+
                DS (Debug store)
+
                ACPI (ACPI supported)
+
                MMX (MMX technology supported)
+
                FXSR (FXSAVE and FXSTOR instructions supported)
+
                SSE (Streaming SIMD extensions)
+
                SSE2 (Streaming SIMD extensions 2)
+
                SS (Self-snoop)
+
                HTT (Multi-threading)
+
                TM (Thermal monitor supported)
+
                PBE (Pending break enabled)
+
        Version: Intel(R) Xeon(R) Platinum 8180 CPU @ 2.50GHz
+
        Voltage: 1.6 V
+
        External Clock: 100 MHz
+
        Max Speed: 4000 MHz
+
        Current Speed: 2500 MHz
+
        Status: Populated, Enabled
+
        Upgrade: Other
+
        L1 Cache Handle: 0x004D
+
        L2 Cache Handle: 0x004E
+
        L3 Cache Handle: 0x004F
+
        Serial Number: Not Specified
+
        Asset Tag: UNKNOWN
+
        Part Number: Not Specified
+
        Core Count: 28
+
        Core Enabled: 28
+
        Thread Count: 56
+
        Characteristics:
+
                64-bit capable
+
                Multi-Core
+
                Hardware Thread
+
                Execute Protection
+
                Enhanced Virtualization
+
                Power/Performance Control
+
 
+
 
+
  Handle 0x0054, DMI type 4, 48 bytes
+
  Processor Information
+
        Socket Designation: CPU2
+
        Type: Central Processor
+
        Family: Xeon
+
        Manufacturer: Intel(R) Corporation
+
        ID: 54 06 05 00 FF FB EB BF
+
        Signature: Type 0, Family 6, Model 85, Stepping 4
+
        Flags:
+
                FPU (Floating-point unit on-chip)
+
                VME (Virtual mode extension)
+
                DE (Debugging extension)
+
                PSE (Page size extension)
+
                TSC (Time stamp counter)
+
                MSR (Model specific registers)
+
                PAE (Physical address extension)
+
                MCE (Machine check exception)
+
                CX8 (CMPXCHG8 instruction supported)
+
                APIC (On-chip APIC hardware supported)
+
                SEP (Fast system call)
+
                MTRR (Memory type range registers)
+
                PGE (Page global enable)
+
                MCA (Machine check architecture)
+
                CMOV (Conditional move instruction supported)
+
                PAT (Page attribute table)
+
                PSE-36 (36-bit page size extension)
+
                CLFSH (CLFLUSH instruction supported)
+
                DS (Debug store)
+
                ACPI (ACPI supported)
+
                MMX (MMX technology supported)
+
                FXSR (FXSAVE and FXSTOR instructions supported)
+
                SSE (Streaming SIMD extensions)
+
                SSE2 (Streaming SIMD extensions 2)
+
                SS (Self-snoop)
+
                HTT (Multi-threading)
+
                TM (Thermal monitor supported)
+
                PBE (Pending break enabled)
+
        Version: Intel(R) Xeon(R) Platinum 8180 CPU @ 2.50GHz
+
        Voltage: 1.6 V
+
        External Clock: 100 MHz
+
        Max Speed: 4000 MHz
+
        Current Speed: 2500 MHz
+
        Status: Populated, Enabled
+
        Upgrade: Other
+
        L1 Cache Handle: 0x0051
+
        L2 Cache Handle: 0x0052
+
        L3 Cache Handle: 0x0053
+
        Serial Number: Not Specified
+
        Asset Tag: UNKNOWN
+
        Part Number: Not Specified
+
        Core Count: 28
+
        Core Enabled: 28
+
        Thread Count: 56
+
        Characteristics:
+
                64-bit capable
+
                Multi-Core
+
                Hardware Thread
+
                Execute Protection
+
                Enhanced Virtualization
+
                Power/Performance Control
+
 
+
== Server Specification ==
+
 
+
The new FD.io CSIT-CPL lab (is expected to contain|contains) following hardware server configurations:
+
 
+
<pre>
+
1. Type-1: Purpose - (Intel Xeon Processor) SUT for SW Data Plane Workload i.e. VPP, testpmd.
+
    - Quantity: TBD based on testbed allocation.
+
    - Physical connectivity:
+
        - IPMI and host management ports.
+
        - NIC ports connected into 2-node and 3-node topologies.
+
    - Main HW configuration:
+
        - Chassis: SuperMicro SYS-7049GP-TRT.
+
        - Motherboard: SuperMicro X11DPG-QT.
+
        - Processors: 2* Intel Platinum 8180 2.3 GHz.
+
        - RAM Memory: 16* 16GB DDR4-2666MHz.
+
        - Disks: 2* 1.6TB 6G SATA SSD.
+
    - NICs configuration:
+
        - Numa0: (x16, x16, x16 PCIe3.0 lanes)
+
            - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
+
            - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
+
            - PCIe Slot9 5e:00.xx: FUTURE ConnectX5-2p100GE Mellanox.
+
        - Numa1: (x16, x16, x16 PCIe3.0 lanes)
+
            - PCIe Slot6 86:00.xx: empty.
+
            - PCIe Slot8 af:00.xx: empty.
+
            - PCIe Slot10 d8:00.xx: empty.
+
2. Type-2: Purpose - (Intel Xeon Processor) TG for T-Rex.
+
    - Quantity: TBD based on testbed allocation.
+
    - Physical connectivity:
+
        - IPMI and host management ports.
+
        - NIC ports connected into 2-node and 3-node topologies.
+
    - Main HW configuration:
+
        - Chassis: SuperMicro SYS-7049GP-TRT.
+
        - Motherboard: SuperMicro X11DPG-QT.
+
        - Processors: 2* Intel Platinum 8180 2.3 GHz.
+
        - RAM Memory: 16* 16GB DDR4-2666MHz.
+
        - Disks: 2* 1.6TB 6G SATA SSD.
+
    - NICs configuration:
+
        - Numa0: (x16, x16, x16 PCIe3.0 lanes)
+
            - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
+
            - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
+
            - PCIe Slot9 5e:00.xx: FUTURE ConnectX5-2p100GE Mellanox.
+
        - Numa1: (x16, x16, x16 PCIe3.0 lanes)
+
            - PCIe Slot6 86:00.xx: empty.
+
            - PCIe Slot8 af:00.xx: empty.
+
            - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
+
3. Type-3: Purpose - (Arm hip07-d05 Processor) SUT for SW Data Plane Workload i.e. VPP, testpmd.
+
    - Quantity: 2
+
    - Physical connectivity:
+
        - IPMI(?) and host management ports.
+
        - NIC ports connected into 3-node topology.
+
    - Main HW configuration:
+
        - Chassis: Huawei TaiShan 2280.
+
        - Processors: 1* hip07-d05 ~ 64* Arm Cortex-A72
+
        - RAM Memory: 8* 16GB DDR4-2400MT/s
+
        - Disks: 1* 4TB SATA HDD
+
    - NICs configuration:
+
        - PCIe Slot2 e9:00.xx: connectx4-2p25GE Mellanox.
+
        - PCIe Slota 11:00.xx: 82599-2p10GE Intel.
+
4. Type-4: Purpose - (Arm Armada 8040 Processor) SUT for SW Data Plane Workload i.e. VPP, testpmd.
+
    - Quantity: 3
+
    - Physical connectivity:
+
        - Host management ports.
+
        - NIC ports connected into 2-node and 3-node topologies.
+
    - Main HW configuration:
+
        - Chassis: MACCHIATObin.
+
        - Processors: 1* Armada 8040 ~ 4* Arm Cortex-A72
+
        - RAM Memory: 1* 16GB DDR4
+
        - Disks: 1* 128GB(?) SATA SDD
+
    - NICs configuration:
+
        - pp2-2p10GE Marvell (on-chip Ethernet ports ; marvell plugin in VPP)
+
5. Type-5: Purpose - (Intel Atom Processor) SUT for SW Data Plane Workload i.e. VPP, testpmd.
+
    - Quantity: TBD based on testbed allocation.
+
    - Physical connectivity:
+
        - Management: serial Port (usb) for console
+
        - NIC ports connected into 2-node.
+
    - Main HW configuration:
+
        - Chassis: Netgate XG-2758-1u
+
        - Processors: 1* Rangeley (Atom) C2758 2.4 GHz
+
        - RAM Memory: 16GB ECC
+
        - Disks: 150 GB
+
    - NICs configuration:
+
        - 2x 10Gb Intel 82599ES
+
        - 4x 1GB Intel I354
+
6. Type-6: Purpose - (Intel Xeon Processor) SUT for VPP_Device functional tests.
+
    - Quantity: 1.
+
    - Physical connectivity:
+
        - IPMI and host management ports.
+
        - NIC ports connected into 2-node and 3-node topologies.
+
    - Main HW configuration:
+
        - Chassis: SuperMicro SYS-7049GP-TRT.
+
        - Motherboard: SuperMicro X11DPG-QT.
+
        - Processors: 2* Intel Platinum 8180 2.3 GHz.
+
        - RAM Memory: 16* 16GB DDR4-2666MHz.
+
        - Disks: 2* 1.6TB 6G SATA SSD.
+
    - NICs configuration:
+
        - Numa0: (x16, x16, x16 PCIe3.0 lanes)
+
            - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
+
            - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
+
            - PCIe Slot9 5e:00.xx: empty.
+
        - Numa1: (x16, x16, x16 PCIe3.0 lanes)
+
            - PCIe Slot6 86:00.xx: empty.
+
            - PCIe Slot8 af:00.xx: empty.
+
            - PCIe Slot10 d8:00.xx: empty.
+
7. Type-7: Purpose - Ixia PerfectStorm One Appliance TG for TCP/IP performance tests.
+
    - Quantity: 1.
+
    - Physical connectivity:
+
        - Host management interface: 10/100/1000-BaseT.
+
        - 8-port 10GE SFP+ integrated NIC.
+
    - Main HW configuration:
+
        - Chassis: PS10GE4NG.
+
        - Motherboard: SuperMicro X11DPG-QT.
+
        - Processors: Quad-Core, Intel Processor.
+
        - HW accelerators: FPGA offload.
+
        - RAM Memory: 64GB.
+
        - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
+
        - Physical Interfaces: 4 * 10GE SFP+.
+
        - Operating System: Native IxOS.
+
    - Interface configuration:
+
        - Port-1: 10GE SFP+.
+
        - Port-2: 10GE SFP+.
+
        - Port-3: 10GE SFP+.
+
        - Port-4: 10GE SFP+.
+
8. Type-8: Purpose - (Intel Xeon Processor) SUT for TCP/IP host stack tests.
+
    - Quantity: 1.
+
    - Physical connectivity:
+
        - IPMI and host management ports.
+
        - NIC ports.
+
    - Main HW configuration:
+
        - Chassis: SuperMicro SYS-7049GP-TRT.
+
        - Motherboard: SuperMicro X11DPG-QT.
+
        - Processors: 2* Intel Platinum 8180 2.3 GHz.
+
        - RAM Memory: 16* 16GB DDR4-2666MHz.
+
        - Disks: 2* 1.6TB 6G SATA SSD.
+
    - NICs configuration:
+
        - Numa0: (x16, x16, x16 PCIe3.0 lanes)
+
            - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
+
            - PCIe Slot4 3b:00.xx: empty.
+
            - PCIe Slot9 5e:00.xx: empty.
+
        - Numa1: (x16, x16, x16 PCIe3.0 lanes)
+
            - PCIe Slot6 86:00.xx: empty.
+
            - PCIe Slot8 af:00.xx: empty.
+
            - PCIe Slot10 d8:00.xx: empty.
+
</pre>
+
 
+
=== Server firmware inventory ===
+
 
+
<pre>
+
Host.         IPMI IP. BIOS. CPLD.          Aptio SU. CPU Microcode.     PCI Bus. ME Operation FW.        X710 Firmware.                 XXV710 Firmware.                i40e.
+
s1-t11-sut1.    10.30.50.47.    2.0b.  03.B1.03. 2.19.1268. 02000043.     A5.01.12. 4.0.4.294.         NoNIC.                         NoNIC.                         2.1.14-k.
+
s2-t12-sut1.    10.30.50.48.    2.0b. 03.B1.03. 2.19.1268. 02000043.     A5.01.12. 4.0.4.294.         5.05 0x80002922 1.1313.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
+
s3-t21-sut1.    10.30.50.41.    2.0b. 03.B1.03. 2.19.1268. 02000043.     A5.01.12. 4.0.4.294.         5.05 0x80002922 1.1313.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
+
s4-t21-tg1.    10.30.50.42. 2.0b. 03.B1.03. 2.19.1268. 02000043.     A5.01.12. 4.0.4.294.         5.05 0x80002922 1.1313.0. 6.01 0x80003554 1.1747.0.      2.1.14-k.
+
s5-t22-sut1.    10.30.50.49. 2.0b. 03.B1.03. 2.19.1268. 02000043.     A5.01.12. 4.0.4.294.         5.05 0x80002922 1.1313.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
+
s6-t22-tg1.    10.30.50.50. 2.0b. 03.B1.03. 2.19.1268. 02000043.     A5.01.12. 4.0.4.294.         5.05 0x80002922 1.1313.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
+
s7-t23-sut1.    10.30.50.51. 2.0b. 03.B1.03. 2.19.1268. 02000043.     A5.01.12. 4.0.4.294.         5.05 0x80002922 1.1313.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
+
s8-t23-tg1.    10.30.50.52. 2.0b. 03.B1.03. 2.19.1268. 02000043.     A5.01.12. 4.0.4.294.         5.05 0x80002922 1.1313.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
+
s9-t24-sut1.    10.30.50.53. 2.0b. 03.B1.03. 2.19.1268. 02000043.     A5.01.12. 4.0.4.294.         5.05 0x80002922 1.1313.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
+
s10-t24-tg1.    10.30.50.54. 2.0b. 03.B1.03. 2.19.1268. 02000043.     A5.01.12. 4.0.4.294.         5.05 0x80002922 1.1313.0. 6.01 0x80003554 1.1747.0.      2.1.14-k.
+
s11-t31-sut1.  10.30.50.43. 2.0b. 03.B1.03. 2.19.1268. 02000043.     A5.01.12. 4.0.4.294.         5.05 0x80002922 1.1313.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
+
s12-t31-sut2.  10.30.50.44. 2.0b. 03.B1.03. 2.19.1268. 02000043.     A5.01.12. 4.0.4.294.         5.05 0x80002922 1.1313.0. 6.01 0x80003554 1.1747.0.      2.1.14-k.
+
s13-t31-tg1.    10.30.50.45. 2.0b. 03.B1.03. 2.19.1268. 02000043.     A5.01.12. 4.0.4.294.         5.05 0x80002922 1.1313.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
+
s14-t32-sut1.  10.30.50.55. 2.0b. 03.B1.03. 2.19.1268. 02000043.     A5.01.12. 4.0.4.294.         5.05 0x80002922 1.1313.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
+
s15-t32-sut2.  10.30.50.56. 2.0b. 03.B1.03. 2.19.1268. 02000043.     A5.01.12. 4.0.4.294.         5.05 0x80002922 1.1313.0. 6.01 0x80003554 1.1747.0.      2.1.14-k.
+
s16-t32-tg1.    10.30.50.57. 2.0b. 03.B1.03. 2.19.1268. 02000043.     A5.01.12. 4.0.4.294.         5.05 0x80002922 1.1313.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
+
s19-t33t34-tg1. 10.30.50.46. 2.0b. 03.B1.03. 2.19.1268. 02000043.     A5.01.12. 4.0.4.294.         5.05 0x80002922 1.1313.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
+
</pre>
+
 
+
== Initial Build (Deprecated) ==
+
 
+
=== Physical Connectivity within Testbeds ===
+
 
+
==== 2-Node Xeon ====
+
 
+
One 2-Node testbeds are constructed by connecting 8 Xeon servers using below specification:
+
 
+
1. testbed21:
+
    - ring3 40GE-ports xl710-2p40GE on SUT
+
        - t21-tg1-c4/p1 to t21-sut1-c4/p1.
+
        - t21-sut1-c4/p2 to t21-tg1-c4/p2.
+
 
+
==== 3-Node Xeon ====
+
 
+
1. testbed31:
+
    - ring1 10GE-ports x710-2p10GE on SUTs:
+
        - t31-tg1-c2/p1 to t31-sut1-c2/p1.
+
        - t31-sut1-c2/p2 to t31-sut2-c2/p2.
+
        - t31-sut2-c2/p1 to t31-tg1-c2/p2.
+
    - ring2 10GE-ports x710-2p10GE on SUT:
+
        - t31-tg1-c4/p1 to t31-sut1-c4/p1.
+
        - t31-sut1-c4/p2 to t31-sut2-c4/p2.
+
        - t31-sut2-c4/p1 to t31-tg1-c4/p2.
+
 
+
==== 2-Node Atom ====
+
 
+
1. testbed35:
+
    - (tbd)
+
 
+
==== 3-Node Atom ====
+
 
+
1. testbed35:
+
    - (tbd)
+

Revision as of 18:14, 13 August 2018

Content has been moved to FD.io CSIT testbeds - Xeon Skylake, Arm, Atom.